Download Print this page

Maintenance - Blackridge BRS50 Manual

50lpm quiet portable inflator for general lightduty tasks around the home

Advertisement

ADJUSTING THE PRESSURE
To adjust the outlet air pressure, use the
red coloured
regulator knob and check the pressure on the outlet pressure
gauge, Pic. 7.
If the pressure needs to be lower,
turn anti clockwise.
If the pressure needs to be higher, turn clockwise.
Use the gauge to ensure you set the correct working pressure.
Note: Different air tools require different operating pressures.
Always check with the tool manufacturer if unsure.
SAFETY VALVE
Pic. 8
NOTE: When checking the safety valve ALWAYS wear safety
glasses.
To check the operation of the safety valve the air tank will
need to be full. Gently pull the ring outwards. This should
release air under pressure. Release the ring and this should
stop the air out fl ow once the pressure has dropped.
If the safety valve does NOT work in this manner, STOP the
infl ator immediately and have the infl ator checked / serviced
by an authorised service centre.
IMPORTANT
NOTE
This infl ator has been supplied with no adjustable
regulator and gauge.
Outlet pressure is 8 Bar (115 PSI).
If you require a lower pressure for your air tool please
buy an adjustable regulator and gauge from your
stockist.
PIC. 7
Regulator
AIR TAP
Outlet tap
Pic. 9
The air tap will need to be opened to allow the air to fl ow to
Outlet
the attached air tool.
pressure
gauge
To open air tap rotate the handle so that it lines up with the
fi ttings and hose, not supplied.
Tank pressure
To close air tap rotate the handle so that it is at 90º to the
gauge
fi ttings and hose, not supplied.
DRAIN TAP
Pic. 10
After use open the drain tap to drain excess air and any
moisture. The excess air will also help purge the moisture.
Leave the drain tap open when infl ator is not in use, so any
moisture can continue to drain
To open the drain tap pull the lever down
to vertical.
To seal the drain tap push the lever up
to horizontal.
NOTE: Remember to seal the drain tap before starting the
infl ator.

MAINTENANCE

Daily: Before Use
1. Seal the tank drain tap,
see above, Pic. 10.
2. Check safety valve operation,
see page 13, Pic. 8.
After Use
1. Open the tank drain tap,
see above, Pic. 10.
2. Wipe down the infl ator.
3. Store safely and securely.
13
PIC. 8
Pull to check
operation

Hide quick links:

Advertisement

loading