Service & Maintenance - Homecrest CF-12 Manual

Fire table
Hide thumbs Also See for CF-12:
Table of Contents

Advertisement

Although the frequency of appliance servicing and maintenance will depend on the use and the type of installation, a qualified
service technician should perform an appliance check-up annually. Storage of an appliance indoors is permissible only if the cylinder
is disconnected and removed from the appliance.
Note: The use of a vinyl table cover is highly recommended to keep your fire pit table and burner looking new and ensuring extended
trouble-free operation.
RISK OF INJURY OR PROPERTY DAMAGE. BEFORE SERVICING:
• Turn off utilities to the appliance.
• Ensure the appliance is completely cooled.
ANNUAL INSPECTION BY QUALIFIED TECHNICIAN RECOMMENDED.
CHECK:
• Obstructions of combustion and ventilation air.
• Condition of the burner assembly.
• Burner ignition and operation.
• Burner air shutter adjustment.
• Gas connections and fittings.
MAINTENANCE AND SERVICE TASKS
For service calls: Contact the dealer your product was purchased from first.
Contact Homecrest Outdoor Living at 218-631-1000 if further assistance is needed.
INSPECT
1
2
Burner Assembly
3
4
1
2
3
Burner Ignition
and Operation
4
5
6
Gas Hose and Regulator
1
SERVICE & MAINTENANCE
DANGER
WARNING
CAUTION
NOTICE
DANGER
WARNING
CAUTION
RISK OF:
NOTICE
• Fire.
• Delayed ignition
• Exposure to combustion fumes.
• Odors.
Remove the decorative glass and examine the burner. Vacuum and wipe out as needed. Use
caution when cleaning these areas.
Inspect for warping and corrosion. Repair as necessary.
Check the hose connecting the LP gas cylinder to ensure it is not damaged. Replace as necessary.
Verify air shutter area is clean.
Verify all gas connections are tight and leak-free.
Clean burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.
Inspect for flame problems.
Verify air shutter is clear of dust and debris and is in the correct position for the gas type being used.
Inspect the orifice for soot, dirt or corrosion.
Verify manifold and inlet pressures. Adjust regulator as required.
The gas hose with regulator supplied with appliance must be used for LP installations. The
replacement must be those specified by the appliance manufacturer.
or explosion.