GAS HOOK-UP & INFORMATION
C. GAS CONNECTION (CONTINUED)
FIRE RISK.
EXPLOSION RISK:
• Gas build-up during line purge may ignite.
• Purge should be performed by a qualified technician.
• Ensure adequate ventilation.
• Ensure there are no ignition sources such as sparks or open flames.
A small amount of air will be in the gas supply lines. When first lighting the appliance it will take a short time for the air to purge
from the lines. Subsequent lighting of the unit will not require such purging.
CHECK FOR GAS LEAKS.
FIRE RISK.
EXPLOSION RISK.
ASPHYXIATION RISK:
• Check all fittings and connections.
• Do not use open flame.
• After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially
available leak check solution. Be sure to rinse off all leak check solution. Be sure to rinse off all leak check solution
following testing.
Fittings and connections may have loosened during shipping and handling.
D. LP GAS SUPPLY
• The pressure regulator and hose assembly supplied with LP models must be used. Replacement pressure regulators and hose
assemblies must be those specified in this manual.
• The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the specifications for LP
gas cylinders of the U.S. Department of Transportation (DOT).
• Cylinders must be stored outdoors in a well ventilated area out of the reach of children. Disconnected cylinders must have
threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed area.
• Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (natural gas line or LP gas
cylinder).
• The LP gas cylinder supply system must be arranged for vapor withdrawal.
• The LP gas cylinder used must include a collar to protect the cylinder valve.
• When an LP model is not in use, the LP gas must be turned off at the supply cylinder.
• The specific size and capacity of the cylinder(s) to be used: 20 lb or hard plumbed to propane tank.
10 | www.homecrest.com
DANGER
WARNING
CAUTION
NOTICE
DANGER
WARNING
CAUTION
NOTICE

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CF-12 and is the answer not in the manual?

Questions and answers

Eric Germain
April 24, 2025

What is the BTU rating and the recommended natural gas orifice size for Homecrest Fire Table model 12-8942SSG-15 ASY14? It is a 42" X 42" table with a 20 " round fire pit purchased in 2016

User image 680acfd7ee5e2

Related Products for Homecrest CF-12

This manual is also suitable for:

Cf-1224Nf-719Nf-16Cf-20

Table of Contents