Summary of Contents for Alpha Technologies BlueGate ISDN

  • Page 1 G A T E BlueGate ISDN Installation and Programming Instruction Manual v 6.5...
  • Page 2 Basic general features: • Connection to the exchange through ISDN S0 interface with DSS1 signalling in NT mode • POINT TO POINT or POINT TO MULTIPOINT exchange S0 interface • Connection to DTMF extension line through direct dialling • Connection directly to 2 operators or determined lines up called SIM card •...
  • Page 3: Optional Modules

    BlueGate ISDN Basic model with the properties described above. BlueGate ISDN synchro Moreover, input for synchronization from another ISDN line (exchange line). This type has to be used for exchanges with more ISDN lines that are not able to handle different ISDN synchronization of individual lines by configuration setting.
  • Page 4 • Length of initial report up to 10 seconds for each GSM module Remote configuration module – remote setting of parameters using a modem • Data transfer and communication rate of 9,600 Bd Properties of the other modules (RS-232, etc.) are described in separate manuals.
  • Page 5 ISDN installation on BlueGate ISDN ISDN RS-232 Adapter 9-15V min. 1A ISDN configuration: ISDN configuration is provided through links on the ISDN board (interconnected links are black coloured). Currently, only the LT-S mode (preset from the factory) is supported. LT-S mode setting: ISDN operates in the function of a public telephone network in this mode, i.e.
  • Page 6 ISDN installation on BlueGate ISDN synchro Indication of active Indication of active communication line synchronization line Communication line Synchronization line connector connector Moreover, the gate is provided with a synchronization input. The cable leading from this input can be connected in parallel with permanently activated S (e.g.
  • Page 7 ISDN installation on BlueGate ISDN router Indication of active Indication of active output line input line Input ISDN line Output ISDN line Moreover, the gate is provided with an ISDN input. The cable leading from this input can be connecte d to the former ISDN line (an exchange line).
  • Page 8 The gate is to be mounted on the wall using 2 holes in the yoke on the back. A suitable position for the gate should be selected on the basis of several factors: • The distance from the exchange – potential interference with other lines on the exchange by GSM emitting.
  • Page 9 Connection of "magnetic aerial" (aerial with magnetic foot). When connecting a "magnetic" aerial to the gate, make sure that their position is on a larger iron object because this object creates a counterbalance of the size where the size of the effective radiated power is dependent above all.
  • Page 10: Possible Problems When Putting Into Operation

    Possible problems when putting into operation None of the LEDs are lit up. Power supply error. Check connection to the mains and connection of the mains’ adapter to the gate. Quick “logging in” flashing of the red LED has not occurred. The module is not logged in the network: •...
  • Page 11 One or both red LEDs on the front silver panel are lit up: • Have the gate tested by an authorized service company. The green LED indicating line activation after cable connection will not light up: • Check the cable and its connection. The green LED indicating PBX line activation will not light up attempting connection: •...
  • Page 12 Positioning routine The routine is intended for setting all the necessary gate parameters and detecting error conditions. The parameters are being set as well as the error conditions can be saved for later utilization. It is intended for Windows 3.1 to 2000 systems. Installation: Start the “Install“...
  • Page 13 Writing the parameters being set in the gate: To enable communication with the gate, it is always necessary to enter an access password identical with the password set in the gate. To save the parameters currently set in the program in the gate, click on the “Write”...
  • Page 14 program, the file (firm.bgi) with the factory setting will be read automatically. The file with this name cannot be saved from the program (in order to prevent in its re -writing). Repeated reading the file with the factory setting can be performed anytime using the “factory setting”...
  • Page 15 Call charg (taxation): The “Taxation” field is untended for activation of taxation impulses. After marking a field, it is possible to select in the “Impulse after every” field the interval between individual impulses. If zero has been selected in the field, the taxation impulse is only one at the moment of establishing connection.
  • Page 16 Permitted direction: Up to 12 blocks of enabled directions can be selected in each GSM module. The table of the enabled directions is accessible after clicking on the “Enabled directions” button. If the table is not filled in, all directions are enabled. 1- up to 8-digit numbers can be written in the first column of the table.
  • Page 17 closed automatically and a check of data will be performed before transfer. In the event of errors in the tables, transfer will be blocked. After clearing the errors, transfer has to be repeated. Direct dialling code selection: The incoming calls can be handled in two ways: All calls can be automatically connected to a selected extension connected...
  • Page 18 OGM module Message recording: The gate can be provided additionally with a board with a digital recorder of “messages” individual channels. When collecting an incoming call through direct dialling, these messages are always replayed. Recording of the message is possible by 2 ways: 1.
  • Page 19 ISDN parameters selection Max.digits: telephones Setting protocol on S – PTP or connected to the GSM gate PTMP. In case of PTPM, MSNs are mostly include selected in direct dialling code, while pushbutton establishing a direct dialling identifier) for PTP. connection dialled number as GSM telephones.
  • Page 20 Redir. To ISDN : Re-routing outgoing GSM calls back in ISDN when GSM is busy (only the “router“ version) : If this selection has been marked, the calls will be routed back in the ISDN network (as if the gate would not be included in the line) if the gate is busy (gate call with one SIM, GSM signal drip out –...
  • Page 21: Remote Configuration Module

    • Received Signal Strength, Receiving level of the BCCH: signal power is one of the most important p arametr for voice connection quality. o -113 to -99 dBm: very bad signal – it is impossible to use any services via GSM network. o -98 to -83 dBm: bad signal –...
  • Page 22 Requirements for the modem: • GSM, ISDN or modem for analogue commutated line connected to COM1 – COM4 (it can be even a virtual one formed through USB). • Auto-bauding or fixed communication rate set to 9,600 Potential other requirements for modem setting given by the communication network connected that are usually to be set in the initialising chain have to be located in the initialising chain in the national configuration file gsmset.cfg in the directory...
  • Page 23 an Outlook directory with the appropriate items (again, csv format separated with commas). The names of individual items or columns should be “name“, “modem“, “file“. The “na me“ field is to be used to save an identifier (name of location, etc.) of the gate.
  • Page 24 corresponding error message and will terminate connection automatically again and the modem will hang up. Ranges of values of settings of individual parameters Parameter No. of digits Range 0000 - 9999 Pulse each 1 - 2 0 - 99 Volume GSM 1 - 7 Volume ISDN 1 - 4...
  • Page 25 the cursor over) on the selected cell and start writing, the complete value in the cell will be rewritten. The complete value in a cell can be again deleted only using the Backspace key. The value in a cell can be saved either using the Enter key or only after crossing over with the cursor or mouse clicking on another cell.