Page 3
Statistic In Use ..................... 36 GSM Modules Statistics..................36 Appendix ..........................37 Description of cdr line......................37 Description of status from GSM modules................38 Description of Alarm message from GSM modules ............39 Technical Conditions for Installation ................... 41 PRIma Gate...
Page 4
The manufacturer cannot be held responsible for any damages that occurred due to incorrect use of this product in contradiction to this manual. The guarantee terms do not cover damages of the product caused by rough handling, incorrect storage or by exceeding the quoted technical parameters. PRIma Gate...
You can manage the Gateway using a Configuration SW running under the Windows XP, Vista, Windows 7 via USB or LAN port • Diagnostics of ISDN lines, ISDN lines Credit, GSM Modules Status and Credit • Status of modules with signal quality • Statistics PRIma Gate...
Signal is present but it is not OK DARK FLASH No signal DARK LIGHT Line is not in configuration DARK DARK LED LAN indicates LAN connection (LED is green – connection is OK, yellow LED flash when LAN is under way). PRIma Gate...
Swapping of the transmitting and receiving connector pair can be made either automatically according NT or TE configuration setting or manually according user setting. For this selection is not need to switch any jumpers on CPU board – all can be made using Gateway configuration software (see Expert Settings). PRIma Gate...
1 per 4 sec the lowest GREEN FLASH 5 per 4 sec the highest GSM module is not presented RED LIGHT RED FLASH other ERRORs see Error states ORANGE LIGHT SMS comunication ERROR fast flash Initialization ORANGE FLASH slow flash No Network PRIma Gate...
This item allows you to save your configuration file to gateway without the Name and the Network setting. Download CDR If you extract from Menu File this item you can download call detailed records (*.csv) from gateway. Description of cdr line is in Appendix. PRIma Gate...
This window is closed after successfull connection. You can use all functions (diagnostics, set-up date) except Update firmware and General reset. Options This section is used for setting Interface, Modem, Password, Language and Date and Time. PRIma Gate...
(60) means how long lasts the connection without exchange of messages. • Dial number Number of SIM card to connecting modem. Language English. Password You can set or change password for access to gateway. Password is saved in Gateway. PRIma Gate...
Gateway is connected). System Information This item displays System information. Reset System restarts the gateway and initializes all Gateway boards (the gateway communication is not discontinued but all current calls and SMS to be sent are terminated!). PRIma Gate...
You can choose the GSM module to reset it. Update Annoucements System writes Annoucements (file *.LMF) into Gateway. System Monitor This pane is used for storing traces from ISDN layers (sending and receiving messages) for possible check in case of problems. PRIma Gate...
LCR (Least Cost Routing), CLIP from GSM and numbers for Mobility Extension. System This pane allows you to assign General parameters, to set network parameters (Network) , parameters for Alarm Indication, CDR and parameters for transmission of received SMS messages. PRIma Gate...
The user of GSM module will hear the annoucement at the begin of the call. Send annoucement for incoming calls from GSM The user of GSM module will hear the annoucement at the begin of the call. You can choose PBX user hears silence or PBX user hears announcement. PRIma Gate...
(in this case you must set DNS server in Network Setting for Remote access) and supervisory program will send the alarm message in syslog protocol. The port number has max 5 digit. If this address isn't filled alarm messages are not sent. PRIma Gate...
(in this case you must set DNS server in Network Setting for Remote access) and supervisory program will send the received SMS message in syslog protocol. If this address isn't filled received SMS messages are not sent. PRIma Gate...
Selection of type of dial tone (330 ms pulse, 330 ms pause, 660 ms pulse, 660 ms pause). Wait for dialing Time (1-60 seconds) to wait for next digit. This timeout causes the end of dialing from PBX. PRIma Gate...
Page 19
If Call progress tone is ON R is no use. Send CONNECT together with ALERTING If you tick off this item the message ALERTING and CONNECT will be sending together. Only for call from PBX to GSM network. Condition for blocked PBX line PRIma Gate...
ISDN cause if GSM modules/groups are busy You can set cause (1-127) if the GSM modules/groups are busy. Default value is cause 3 (No route to destination). 6.2.2 Lines In this section you can set options for each line (PBXE1-A, PSTNE1-B, E1-C, E1-D). Protocol PRIma Gate...
Page 21
Week/Day of credit restoration (1-31) Set week in month (1-4) and day of the week (monday-sunday) when credit is automatic restoring. Day of weekly credit restoration (monday- sunday) Set day of the week (monday-sunday) when credit is automatic restoring. PRIma Gate...
Page 22
You can choose from 3 options of RJ45 pin setting: According to the protocol, Always TE or Always NT. L2 Parameters This setting is not recommended to change. TEI selection (0-127) Gateway identification address (0 by default, 127 max.) PRIma Gate...
First line in the pane Order of synchronization has the highest priority. This section defines properties for GSM modules. There are displayed 4 modules for each module card (max 4 modules x 8 card). PRIma Gate...
Defines assignment GSM modules to GSM group and allows setting SIM card. Configuration • Disable You can define unused GSM card if you tick off Disable. • Echo cancelation You can choose ON/OFF echo. • Roaming You can permit or forbid to register GSM module to roaming. PRIma Gate...
Page 25
PIN code. • Day of credit restoration (1-31) Set day of month when credit is automatic restoring. • Week/Day of credit restoration (1-31) Set week in month (1-4) and day of the week (monday-sunday) when credit is automatic restoring. PRIma Gate...
Page 26
If there are two SIM cards in module you can set parameters of the second SIM card in this window. After blocking the first SIM card the second will be working. Apply to All Modules In this part you can copy setting of current module to another selected modules PRIma Gate...
Routing table for PBX users. If for dialed number does not exist rule in Routing table, this call will be routed to PBX. Other calls (which CLIP is not in list of GSM number) are routed to the extension entered in table extensions. PRIma Gate...
Page 28
Prefix Prefix, which the gateway adds before dialed DTMF numbers. Digits to cut for callback You can define length of cut digits from calling number. Prefix for callback You can define length of inserting digits before calling number. PRIma Gate...
Page 29
Minimal extension length. Maximal count of this extension is 5 extensions. If you set mode Receive and receive all calls which are not in List of GSM numbers are routed to the second extensions (in order). Modules in group Bottom section informs about modules in each group. PRIma Gate...
GSM network according to CLIP table and Routing Table Gateway at each call check line to line and in case that called prefix is same as prefix stored in Routing Table the call will be routed via defined GSM group(s) or via E1-B interface. PRIma Gate...
You can define length of digits, which will be sent. ‘0’ means that length of called number is unknown and end of dial is recognized after timeout defined in Wait for dialing. This parameter can make the call arrangement faster. PRIma Gate...
Default routing profile. CLIP from GSM You can add, change or delete GSM numbers to List of GSM numbers. List of GSM numbers This is list of numbers using in GSM Incoming Groups and Mobility Extension. PRIma Gate...
You can set when number rings (Always, During working hours or Out of working hours). Working Hours You can set the time for beginning and end of working hours for each day of week. You can set days of holidays too PRIma Gate...
Blue indicator signalizes WARNING. E1 lines credit There is information about the credit of E1 lines. Each module has credit X/Y. X is Credit to restore and Y is Remaining credit. If X=0 E1 line is wihtout credit. PRIma Gate...
There is information about each GSM module and its credit. Each module has credit X/Y. X is Credit to restore and Y is Remaining credit from SIM card setting in GSM modules. If X=0 SIM card is wihtout credit. PRIma Gate...
Statistic In Use This pane displays how many modules is current in use (last 13 minutes). GSM Modules Statistics This pane displays how many modules were in use last 24 hours. PRIma Gate...
Cell is not authorized Unauthorized Cell - blocked Cell isn't authorized and module is blocked Description of Alarm CME ERROR Note SIM not inserted CME Error (10) SIM PUK required CME Error (12) SIM failure CME Error (13) PRIma Gate...
Page 40
Description of Alarm PCM ERROR Note Loss of Signal Alarm Indication Signal Loss of Frame Alignment Receive Remote Alarm Frame Error Counter > 0.001 / CRC4 error FEC Data Link Layer Not Active Data Link Layer is not active PRIma Gate...
Clock (master or slave) Master/Slave Connector RJ 45 D channel timeslot Temperature Working temperature range 0°C to + 50°C Relative humidity max. 95% at 40°C Air – condition optional Remote Control Line types Type of line USB2.0 Ethernet10/100 BaseT PRIma Gate...
Need help?
Do you have a question about the PRIma Gate and is the answer not in the manual?
Questions and answers