GPRS
d)
Command details:
AT+REBT
Function:
Restart module
Format:
Set
TX:AT+REBT<CR>
Return:<CR><LF>+OK<CR><LF>
Parameter:None
Description: After the command is executed correctly, the module restarts immediately and enters the transparent transmission mode after restarting.
AT+VER
Function:
Query firmware version
Format:
Set
TX AT+VER<CR><LF>
Return <CR><LF>+OK=<ver><CR><LF>
Parameter:Ver firmware version
description:None
AT+INFO
Function:
Query module type and version
Format:
Set
TX AT+INFO<CR><LF>
return <CR><LF>+OK=<mod_name>,<hw_ver>,<sw_ver><CR><LF>
Parameter:
mod_name module name
hw_ver
sw_ver
description:None
AT+EXAT
Function:
exit command mode,enter transparent transmission mode
Format:
Set
TX AT+EXAT<CR><LF>
return <CR><LF>+OK<CR><LF>
Parameter:None
Description:After the command is executed correctly, the module is switched from command mode to transparent mode.
AT+RESTORE
Function:
Restore factory setting
Format:
Set
TX AT+RESTORE<CR><LF>
return <CR><LF>+OK<CR><LF>
Parameter:None
description:None
AT+UART
Function:
Set/Query UART parameter
Format:
Query
TX:AT+UART<CR>
Return:<CR><LF>+OK=<baudrate>,< parity ><CR><LF>
Set
TX:AT+UART=<baudrate>,< parity ><CR><LF>