Commissioning
2.1.10 Function testing
NOTE
During initial start-up and annual servicing,
make sure that all control, regulating and
safety devices are in full working order and, if
applicable, check for correct adjustment.
Measuring the ionisation current (fig. 56)
Turn the mains power switch to "0" (see fig. 49, item 1).
Remove the casing.
Loosen the connector-and-socket connection of the ionisa-
tion electrode and connect the multimeter in series.
On the measuring device, select the µ-direct current range.
The measuring device must have a resolution of at
least 1 µA (1 micro ampere).
Set mains power switch to "1" (see fig. 49, item 1).
Set the boiler in to partial load by pressing the Service
button "A" once.
Measure the ionisation current. The ionisation current
being checked must measure >2 µA (>2 micro ampere)
direct current.
Enter the reading on the report form.
Set the mains power switch to "0" (see fig. 49, item 1).
Remove multimeter and restore the connector-and-socket
connection to its original state.
Refit the casing and secure the boiler with the radiator key
(see fig. 57).
Set the mains power switch to "1" (see fig. 49, item 1).
2.1.11 Handing over
After completing the installation and commissioning of the
system the installer should hand over to the householder by
the following actions:
Hand over all relevant documentation to the end user and
explain his/her responsibilities under the relevant national
and regional regulations.
Explain and demonstrate the lighting and shutting down
procedures.
NOTE
Always keep the user manual and installation
and servicing instructions available for feed-
back.
Subject to modifications resulting from technical improvements!
Installation and maintenance instructions for Buderus 500 - 24/C and 500 - 28/C • 02/2005
fig. 56 Measuring the ionisation current
fig. 57 Refit casing