Installation
NOTE
It is absolutely essential to ensure, in practice,
that products of combustion discharging from
the terminal cannot re-enter the building or any
other adjacent building through ventilators,
windows, doors, other sources of natural air
infiltration, or forced ventilation/air-condi-
tioning.
If this could occur the appliance MUST be turned off (with the
owners permission), and labelled as unsafe until corrective
action can be taken.
DANGER!
Only use Boulter Buderus flue gas systems.
As other flue gas systems are not tested with
this appliance.
1.7.2
Air supply and flue gas exhaust in a closed
installation
A ventilation cover is integrated into the 500 Series condensing
gas boilers. This cover houses a number of components, such
as the burner and the heat exchanger. Since this ventilation
cover is part of the air supply system, it is vital that it is always
installed correctly.
To ensure optimal operation, the 500 Series appliances must
be connected to a Boulter Buderus horizontal or vertical flue
terminal. These terminals have been developed specifically for
Boulter Buderus condensing gas boilers and have been
comprehensively tested for trouble free operation when
correctly installed.
Standard horizontal flue pack (fig. 13):
– item 1: Flue turret 60/100;
– item 2: Horizontal flue terminal 60/100;
– item 3: Flue finishing kit.
Subject to modifications resulting from technical improvements!
16
Installation and maintenance instructions for Buderus 500 - 24/C and 500 - 28/C • 02/2005
1
fig. 13 Standard horizontal flue pack
fig. 14 Side flue and rear flue installation