Page 1
PERSONAL IMPACTORS MODEL 200 USER GUIDE P/N 6011802, REVISION A JUNE 2018...
Page 3
Introduction Unpacking Principle of Operation PERSONAL IMPACTOR Model 200 Personal MODEL 200 Impactor Description Operation Specifications USER GUIDE Spare Parts and Accessories List Technical Contacts Returning for Service References Appendix A: Impactor Flow Calibration Instructions Appendix B: Typical Model 200 Impactor Pressure Drops...
Page 4
M a n u a l H i s t o r y The following is a manual history of the Personal Impactors Model 200 User Guide (P/N 6011802). Revision Date June 2018...
Page 5
W a r r a n t y Part Number 6011802 / Revision A / June 2018 Copyright TSI Incorporated / 2018 / All rights reserved. Address MSP, A Division of TSI / 5910 Rice Creek Parkway / Shoreview, MN 55126 / USA E-mail Address answers@tsi.com Limitation Of Warranty And Liability...
Page 6
SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss.
C o n t e n t s Manual History .................... ii Warranty ..................... iii Contents ...................... v Introduction ....................1 Unpacking ....................2 Principle of Operation ................2 Model 200 Personal Impactor Description ..........2 Operation ..................... 4 Disassembly Procedure ................4 Coating the Impaction Plate ..............
Page 8
(This page intentionally left blank) Personal Impactor Model 200...
I n t r o d u c t i o n I M P O R T A N T This User Guide contains important safety and operating instructions for the Model 200 Personal Impactor. Any use other than that intended by the manufacturer in this user guide is not proper use of the Model 200 Personal Impactor.
U n p a c k i n g Carefully remove the Model 200 Personal Impactor from its shipping box and visually inspect the impactor for any damage it may have suffered in transit. Please contact your shipping company if any damage is noted. The Model 200 Personal Impactor is shipped with this User Guide.
Page 11
Figure 2. Schematic Diagram of Personal Impactor. Phillips flat head screws are normally used instead of the spanner screws User Guide...
Figure 3. Model 200 Personal Impactor in Clamping Device Figure 4. Assembled Model 200 Personal Impactor O p e r a t i o n Disassembly Procedure The Model 200 Personal Impactor is disassembled by removing the two screws holding the nozzle cap to the base. Optional spanner screws (flat head with two holes) and matching screw driver could be used for applications where there is a risk of the wearer opening the sampler.
tissue to the porous surface. If oil drips from the ring when it is held vertically, too much has been applied. After each use, the particles on the impaction ring should be removed by scraping the surface with a knife or razor blade and, periodically, more oil should be added.
NO T E The inlet flow rate to the Model 200 Personal Impactor must be measured and controlled to within ±5% of the specified flow rate. The specified cut size for the Model 200 Personal Impactor is valid as long as the required flow rate is maintained by the sampling pump throughout the complete sampling period.
R e t u r n i n g f o r S e r v i c e and complete the on-line “Return Visit our website at http://rma.tsi.com Merchandise Authorization” form or call TSI at 1-800-680-1220 (USA), (651) 490-2860, or 001 651 490 2860 (International) for specific return instructions.
A p p e n d i x A : I m p a c t o r F l o w C a l i b r a t i o n I n s t r u c t i o n s A correct flow calibration of the impactor requires a special attachment known as the Flow Calibration Cap (Figure 5).