Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Velleman Manuals
Multimeter
DVM4200
User manual
Mod E Description - Velleman DVM4200 User Manual
6600 counts multi function multimeter
Hide thumbs
Also See for DVM4200
:
User manual
(72 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
page
of
72
Go
/
72
Bookmarks
Advertisement
Available languages
EN
FR
DE
ES
NL
More
Available languages
ENGLISH, page 1
FRANÇAIS, page 30
DEUTSCH, seite 56
ESPAÑOL, página 43
DUTCH, pagina 17
all except
Hz/Duty
power off
all except
Hz/Duty and
6.4
Mod
e description
DATA HOLD
D mode
• In Data Ho
old mode, the displ
• Press the
HOLD button to en
• When Data
a Hold mode is ena
manual ra
nging mode.
• To exit Da
ata Hold mode, pres
Manual / A
uto range mode
• The meter
r has both manual a
• In the aut
o range mode, the
This allows
s you to switch test
meter is in
n the auto range mo
• In the ma
nual ranging mode,
the user to
o override auto ran
• The meter
r defaults to auto ra
more than
n one range.
• To enter a
and exit the manual
successive
ely to scroll through
• To exit the
e manual ranging m
seconds. T
The meter returns t
Sleep mode
e
• The Meter
r enters the "sleep m
not used f
for 30 minutes.
• Press any
button or rotate th
• To disable
Sleep mode, hold
Note: slee
ep mode is automat
Relative me
easurement mode
• Relative m
measurement mode
• To enter a
and exit the relative
• Press the
REL
measurem
ment mode. The diff
reading is
displayed. REL is s
• Press the
REL
operation.
6.5
PC L
Link
• The DVM4
4100 has a serial d
• Before con
ntinuing the necess
PC. Insert
the included CD RO
README.p
pdf for the installati
on the scr
een
Notes:
• First ins
stall the PC-link soft
• log in on
n the PC as adminis
UAC (Us
ser Account Control
Center –
– User Account Con
• Connect th
he meter to a USB
22.04.2011
Pre
ess to enter/exit rel
Pre
ess and hold while s
mo
ode.
Pre
ess to measure max
me
easure minimum va
Pre
ess and hold for ±2
mo
ode.
ay is not longer upd
nter Data Hold mode
abled in auto range
ss the HOLD button
and auto range opti
meter selects the b
t points without hav
ode, AUTO is displa
, the range must be
ge and lock the me
ange mode for mea
l range mode press
h the available rang
mode, press and hol
to the auto range m
mode" and blanks t
e rotary switch to w
down the REL
tically disabled whe
e
is available during
e measurement mod
key to store
the measured valu
ference between the
shown on the displa
key for more
e than 2 seconds to
data output function
ary USB driver and
OM into a suitable P
on procedure (Engl
tware followed by t
strator. For Vista/W
l) (via Control Pane
ntrol settings -> Ne
port of a PC using t
DVM4200
lative measurement
switching on to disa
ximum value, press
alues.
s to return to norm
dated.
e. H is shown on th
mode, the meter sw
n
ions.
best range for the in
ving to reset the ra
ayed [F].
e selected manually
eter in a specific ran
surement functions
the RANGE button
es.
ld down RANGE ke
mode and AUTO is d
he display if the me
wake the meter up.
ke
ey while turning the
en PC-Link is runnin
all functions excep
de, start the measu
ue and activate the
e reference value a
ay [J].
o return the meter t
n.
software must be
PC. Locate and open
ish only). Follow th
he USB driver, than
Windows 7 systems,
el – System and Sec
ver notify.)
the included data ca
9
t mode.
able sleep
s again to
mal measuring
he display [I].
witches to
nput detected.
nge. When the
y. This allows
nge.
s that have
n. Press
ey for two
displayed.
eter is on but
meter on.
ng.
t frequency.
urement.
relative
nd subsequent
to normal
installed on the
n the file
e instructions
n restart the PC.
disable the
curity – Action
able.
©Velleman nv
Previous
Page
Next
Page
1
...
6
7
8
9
10
11
12
13
Advertisement
Need help?
Do you have a question about the DVM4200 and is the answer not in the manual?
Ask a question
Go to Questions and Answers
Subscribe to Our Youtube Channel
Related Manuals for Velleman DVM4200
Multimeter Velleman DVM4200 User Manual
6600 counts multi function multimeter (72 pages)
Multimeter Velleman DVM401 User Manual
(41 pages)
Multimeter Velleman DVM4x00 Series User Manual
6600 counts multi function multimeter with usb interface (72 pages)
Multimeter Velleman DVM4 00 Series User Manual
6000 counts multi function multimeter (73 pages)
Multimeter Velleman DVM6243 Manual
(28 pages)
Multimeter Velleman DVM892 User Manual
(50 pages)
Multimeter Velleman DVM860BL Manual
(55 pages)
Multimeter Velleman DVM832 User Manual
(77 pages)
Multimeter Velleman DVM66 Operation Manual
Dual display digital multimeter (17 pages)
Multimeter Velleman DVM94 User Manual
(94 pages)
Multimeter Velleman DVM901 User Manual
Cat ii 700 v/cat iv 600 v (113 pages)
Multimeter Velleman DVM821 User Manual
(75 pages)
Multimeter Velleman DVM830 User Manual
(31 pages)
Multimeter Velleman DVM841 User Manual
Digital multimeter 1999 counts cat. ii 500 v / cat. iii 300 v (87 pages)
Multimeter Velleman DVM811 User Manual
(85 pages)
Multimeter Velleman DVM645BI User Manual
Bench multimeter (26 pages)
Related Products for Velleman DVM4200
Velleman DVM401
Velleman DVM4x00 Series
Velleman DVM4100
Velleman DVM4 00 Series
Velleman DVM205AM
Velleman DVM9912
Velleman DVM1500
Velleman DVM1400
Velleman DVM840
Velleman DVM9915
Velleman DVM3218
Velleman DVM1190
Velleman DVM830L
Velleman DVM855
Velleman DVM101
Velleman DVM852
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the DVM4200 and is the answer not in the manual?