Download Print this page

Vanderbilt AGB800-AM Instruction And Installation Manual page 4

Acoustic glass break detector with antimasking

Advertisement

PROTECTING SEVERAL WINDOWS BY ONE DETEC-
TOR
Detector can protect several windows in one room if the win-
dows are within the coverage area. Make independent DRC
test for each window to be protected. Follow the procedure
above for each window. The detector shall be set to the lowest
Zone number that is the longest range from the detector.
TIMEOUT
Both the AGB800-AM detector and ADT700 tester are
equipped with a timeout feature. The AGB800-AM will stop the
DRC mode and the ADT700 will switch off power if no activity
has happened within 3–4 minutes.
D/N CONTROL (Day/Night)
The D/N makes it possible to remote control the alarm indica-
tions of the detectors and remote reset during DAY->NIGHT
transition. The D/N increases the security of the detector, as it
enables the alarm indications to be concealed in NIGHT mode
without any influence on the relay function.
SELF-TEST
Detector is continuously checking all vital parts responsible for
proper detection of glass break signal using internal self-test
procedure.
ANTI-MASKING
Test of antimasking system:
1. Put the power on. Seal microphone completely with elastic
material like chewing gum or isolation tape.
2. INTRUSION and FAULT relays will open after max. of 180
s signaling masking of microphone.
3. Remove sealing material from microphone. Relays will
close in less than minute.
Issued by Vanderbilt
Clonshaugh Business and Technology Park
Clonshaugh, Dublin 17
D17 KV84, Ireland
www.vanderbiltindustries.com
Doc ID: I-200259
Edition Date: 01.05.2017
TECHNICAL DATA
Type (thickness) of protected glass
Size of protected glass
Max range
Range setting
Supply voltage
Max. voltage ripple
Voltage monitoring
Current consumption quiescent state
D/N signal levels
INTRUSION output, FAULT output
INTRUSION and FAULT relay contact rating
TAMPER contact rating
Intrusion/fault indication
Environmental class
Operating temp. range
Operating humidity range
Housing material
Dimensions [WxHxD]
Security grade
Approvals
ORDERING INFORMATION
Type
Art No.
AGB800-AM
V54535-Z129-A100
Accessory
ADT700
N54535-Z100-A100
© 2017 Vanderbilt
UNDERSTANDING THE LED WHEN THE DETEC-
TOR IS IN OPERATION
LED
Flashes 1–3 times
when powered ON
Off
Permanently on
Permanently on
with 1 blink per 3s
Permanently on
with 2 blinks per 3s
Short blink
UNDERSTANDING THE LED WHEN TESTING THE
DETECTOR WITH ADT700 TESTER
LED
Flickers
Flickers and blinks
Flashes 1.5s
Blinks slowly 1 time each
2.5s after calibration
Blinks slowly 2 times each
2.5s after calibration
Blinks slowly 3 times each
2.5s after calibration
TROUBLESHOOTING
Detector does not respond
 Check the supply voltage and polarity
LED permanently on
 Switch off the detector for a short period
 Check if LED is in latching mode (DIP1=ON)
LED permanently on with 1 dip per 3 s
 Check if microphone not masked with foreign material
LED permanently on with 2 dips per 3 s
 Check supply voltage – should be higher than 7 V
No alarm
 Check the INTRUSION and FAULT relay wiring
 Check the alarm loop wiring
float (4mm), laminated P2, P4 (4mm + 4mm)
min 40 × 40 cm
9m radius/165°
Zone 1 = 4–9m
Zone 2 = 2–4m
Zone 3 = 1–2m
7–30V DC
2 Vpp at 12V, 4 Vpp at 24V
Fault signaled at < 7V
12mA @ 12V, 7mA @ 24V
DAY = D/N open or < 2.5V, NIGHT = D/N > 2.5V
relay
50mA, 50V DC/peak AC, Rs ≤ 30Ω
50mA/50V DC/peak AC
LED
EN50130-5:2011, VdS 2110 Class I
-25°C to +40°C
max. 93% RH
plastic ABS, white
68 x 109 x 40 mm
EN 50131-2-7-1:2012/A1:2013, Grade 3, VdS class B
Description
Acoustic glass break detector G3
Acoustic glass break tester
4 / 4
Detector status
Indication of range setting after power-on
Normal state, no alarms
Intrusion detected – if detector in Latch
mode
Masking detected
Low supply voltage or self-test failure
Antimasking warning – foreign object in
close proximity of microphone
Detector status
In test mode
In calibration mode
Confirms received signal
Set range setting to Zone 1 (4–9m)
Set range setting to Zone 2 (2–4m)
Set range setting to Zone 3 (1–2m)
Weight
0.126Kg
0.743Kg
021_AGB800-AM_I-200259_EN

Advertisement

loading