  • Page 1 Monoblock SANERO M201 User Manual...
  • Page 2: Table Of Contents

    Content Content ..............................2 Introduction ............................. 3 Safety Information ........................... 4 ES Conformity Declaration ........................5 Guarantee Certificate ..........................6 Product Description ..........................7 Technical Parameters ..........................8 Operating Instructions ........................... 10 Positioning of the footrest ........................ 10 Positioning of the backrest ........................ 11 Side folding grab handles ........................
  • Page 3: Introduction

    Introduction Thank you for purchasing a monoblock SANERO M201. To take full advantage of all features of the product, carefully read all instructions and put it onto available place in order to it is accessible for all potential users. Attention This manual contains general instructions for use, operation and maintenance of this product.
  • Page 4: Safety Information

    Integral part of the monoblock SANERO is fastening system ROLFIX, fixing the ambulance cot in ambulance car. MEDIROL Company Ltd. strongly recommended to fasten the monoblock only using fastening system Medirol® ROLFIX F102, which with the monoblock Medirol®SANERO M201 complies with European standard EN 1789 in section 4.5.9.
  • Page 5: Es Conformity Declaration

    336/2004 by which is stated technical requirements at medical means. Producer: MEDIROL s.r.o., Na Strži 126/4, 140 00 Praha 4, Czech Republic, VAT no.: CZ64506592 Manufacturing plant: MEDIROL s.r.o., Dolní Dubňany 58, 671 73 Tulešice, Czech Republic Product´s name and type:...
  • Page 6: Guarantee Certificate

    Guarantee Certificate The producer MEDIROL Ltd. provides a guarantee for each product against defects in materials and workmanship: With two years guarantee- monoblock frame and all its components • pillow • mattress • restraint system • wheels • This warranty does not cover: standard wear •...
  • Page 7: Product Description

    Product Description The monoblock Medirol® SANERO M201 is equipment designed for transport of recumbent patient on paved surface. Standard Features High-strength aluminum construction • Ergonomic design • Fixed patient section allowing cardiac massage • One-hand release, fold-down side rails •...
  • Page 8: Technical Parameters

    Technical Parameters...
  • Page 10: Operating Instructions

    Operating Instructions Positioning of the footrest...
  • Page 11: Positioning Of The Backrest

    Positioning of the backrest...
  • Page 12: Side Folding Grab Handles

    Side folding grab handles...
  • Page 13: Positioning Of The Rear Legs

    Positioning of the rear legs It is not allowed to brake the trolley during positioning – rear swivel wheels have to find their position themselves. During positioning the monoblock always uplift to decrease the action of force at the positioning locker. Handle of monoblock´s carriage during legs positioning, entry and exit from ambulance car always hold from under, as presented at the picture to avoid tripping...
  • Page 14: Positioning Of The Front Legs

    Positioning of the front legs It is not allowed to brake the trolley during positioning – rear swivel wheels have to find their position themselves. During positioning the monoblock always uplift to decrease the action of force at the positioning locker.
  • Page 15: Unlocking Of Front Wheels Whirl

    Unlocking of front wheels whirl Set the brake of monoblock´s carriage...
  • Page 16: Drive Into Ambulance Car

    Drive into ambulance car During drive into ambulance car is possible to take advantege to sequent unlock of the locker front and rear legs in two positions of the operating lever. During drive into ambulance car monoblock must be always in basic transport position.
  • Page 17: Drive Into Ambulance Car

    Drive into ambulance car During drive into ambulance car and unlocking the locker for positioning monoblock always uplift in order to reduce action of force at locker for positioning. During drive out from ambulance car is necessary hold lever of the lock off legs locker during unfold rear legs.
  • Page 18: Basic Accessories

    Basic Accessories Belt system and mattress with pillow Mattress with pillow A – 1806 Anatomical mattress B – 1803 Anatomical pillow Belt system C – 1707 Four-point belt D – 1712 Cross belt E...
  • Page 19: Maintenance

    By use frequency over 200x times a • month maintain inspection every month Revision MEDIROL recommend doing revision regularly. First revision inspection performs after 2 years and then regularly ones a year. Cleaning wash all parts with warm water •...
  • Page 20: Inspectional Note

    Inspectional Note Serial number: Name: Type number: Date: Monoblock All mechanical and screw joints are solid All welded joints are unbroken, without craks No part of framework is not dismounted Overrunning wheels easily rotating, in wheel axis are not any impurities Main riding wheels are tightly attached, freely rotating and without impurities in wheel axis Wheel brake system is fully functional Monoblock can properly drive into ambulance car and drive out from ambulance car...
  • Page 21: Training Note

    Training Note Date Name Type of training...
  • Page 22: Note From Inspection

    Note from inspection Date Performed maintenance Name...
  • Page 23 Customer Care. If you have other questions about the product, its operation or maintenance, ask your dealer. Our dealers have extensive experience with the products MEDIROL. They can help you with your individual questions and find the right solution.