Fujitsu ARYG LHTA 1ph Installation Manual

Indoor unit (duct type)

Advertisement

Quick Links

AIR CONDITIONER
For authorized service personnel only.
INSTALLATIONSANLEITUNG
MANUEL D'INSTALLATION
Pour le personnel de service agrée uniquement.
MANUAL DE INSTALACIÓN
Únicamente para personal de servicio autorizado.
MANUALE D'INSTALLAZIONE
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
MANUAL DE INSTALAÇÃO
Somente para o pessoal do serviço técnico autorizado.
РУКОВОДСТВО ПО УСТАНОВКЕ
Внутренний модуль (Канального типа)
Только для авторизованного обслуживающего персонала.
INSTALLATION MANUAL
Indoor Unit (Duct type)
Innengerät (Für Luftkanalsysteme)
Nur für autorisiertes Fachpersonal.
Unité intérieure (Type conduit)
Unidad interior (Tipo ducto)
Unità interna (Tipo di condotto)
Εσωτερική μονάδα (Τύπος αγωγού)
Unidade interior (Tipo conduta)
KURULUM KILAVUZU
İç Ünite (Kanal tipi)
Yalnızca yetkili servis personeli için.
[Original instructions]
PART NO. 9379123143

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ARYG LHTA 1ph

  • Page 1 AIR CONDITIONER INSTALLATION MANUAL Indoor Unit (Duct type) For authorized service personnel only. INSTALLATIONSANLEITUNG Innengerät (Für Luftkanalsysteme) Nur für autorisiertes Fachpersonal. MANUEL D'INSTALLATION Unité intérieure (Type conduit) Pour le personnel de service agrée uniquement. MANUAL DE INSTALACIÓN Unidad interior (Tipo ducto) Únicamente para personal de servicio autorizado.
  • Page 2: Table Of Contents

    INSTALLATION MANUAL Indicates a potentially hazardous situation that may result in CAUTION minor or moderate injury or damage to property. PART NO. 9379123143 Indoor Unit (Duct Type) Read carefully all safety information written in this manual before you install or use the air conditioner.
  • Page 3: Accessories

    2.3. Accessories 3. GENERAL SPECIFICATION 3.1. Selecting the pipe material WARNING • For installation purposes, be sure to use the parts supplied by the manufacturer or other prescribed parts. CAUTION The use of non-prescribed parts can cause serious accidents such as the unit to fall, water leakage, electric shock, or fire.
  • Page 4: Installation Work

    4. INSTALLATION WORK 4.2. Installation dimension Install at least 20mm from the ceiling. WARNING Do not turn on the power until all installation work is complete. Carrying and installation of the unit should be performed by a sufficient number of people and with sufficient equipment that is adequate for the weight of the unit.
  • Page 5: Installing The Drain Hose

    4.3.1. Installing the hangers CAUTION Hanging bolt installation diagram • If an intake duct is installed, take care not to damage the temperature sensor (the temperature sensor is attached to the intake port flange). 1,050 • Be sure to install the air inlet grille and the air outlet grille for air circulation. The 1,000 correct temperature cannot be detected.
  • Page 6: Pipe Installation

    (2) Safety drain Dimension A [mm] There is no need to provide a trap for the safety drain pipe. If the safety drain pipe is Pipe outside diameter Dimension B [mm] Flare tool for R410A, [mm (in.)] connected to the main drain pipe, make the connection below the trap on the main drain clutch type pipe.
  • Page 7: Installing Heat Insulation

    Tighten with 2 wrenches. WARNING Holding wrench • Install sleeves into any holes made in the walls for wiring. Otherwise, a short circuit could result. Flare nut Torque wrench • Use the included connection cables and power cables or ones specified by the manufacturer.
  • Page 8: Wiring System Diagram

    6.2. Connection cable preparation Ring terminal Keep the earth (ground) wire longer than the other wires. Sleeve Power supply cable Earth (Ground) wire Screw with or connection cable special washer Screw with special washer • Use a 4-core wire cable. Ring terminal Ring Cable...
  • Page 9: Remote Controller Setting

    7. REMOTE CONTROLLER SETTING CAUTION When detecting the room temperature using the remote con- Temperature troller, please set up the remote controller according to the sensor following conditions. If the remote controller is not located prop- erly, the correct room temperature will not be detected, and thus abnormal conditions like “not cooled”...
  • Page 10: Function Setting

    (4) Press the SET TEMP. buttons ( ) to select the setting value. 8. FUNCTION SETTING The display flashes as shown to the right during setting value selection. CAUTION • Confirm whether the wiring work for outdoor unit has been finished. •...
  • Page 11 Setting record (4) Auto restart Enable or disable automatic system restart after a power outage. • Record any changes to the settings in the following table. (♦... Factory setting) Setting Setting Value Function Setting (1) Filter sign Setting Description Number Value (2) Cooling room temperature correction ♦...
  • Page 12: Group Control System

    Standard Simultaneous Simultaneous 8.3. Group control system pair twin triple Outdoor Outdoor Outdoor unit 1 unit 2 unit 3 CAUTION • When setting rotary switch, do not touch any other parts on the circuit board directly with your bare hands. Indoor Indoor Indoor...
  • Page 13: Optional Kit Installation (Option)

    9. OPTIONAL KIT INSTALLATION (OPTION) 11. TEST RUN CHECK ITEMS WARNING Regulation of cable differs from each locality, refer in accordance with local (1) Is operation of each button on the remote controller normal? rules. (2) Is the drain normal? (3) Is there any abnormal noise and vibration during operation? This air conditioner can be connected with the following optional kits.
  • Page 14: Error Codes

    • 2-way valve temp. sensor error 13. ERROR CODES • 3-way valve temp. sensor error Heat sink temp. sensor error [Troubleshooting at the remote controller LCD] This is possible only on the wired remote controller. • Sub-cool Heat Ex. gas inlet temp. sensor error [Self-diagnosis] •...