5. Piping Design, Treatment and Installation
Table 5-1
Piping
LNG piping
Fuel gas piping
Fuel oil piping (MDF and HFO)
Lubricating oil piping
Fresh water piping
Sea water piping
Compressed air pipe sizing has to be calculated project specifically. The pipe sizes may be
chosen on the basis of air velocity or pressure drop. In each pipeline case it is advised to
check the pipe sizes using both methods, this to ensure that the alternative limits are not being
exceeded.
Pipeline sizing on air velocity: For dry air, practical experience shows that reasonable
velocities are 25...30 m/s, but these should be regarded as the maximum above which noise
and erosion will take place, particularly if air is not dry. Even these velocities can be high in
terms of their effect on pressure drop. In longer supply lines, it is often necessary to restrict
velocities to 15 m/s to limit the pressure drop.
Pipeline sizing on pressure drop: As a rule of thumb the pressure drop from the starting air
vessel to the inlet of the engine should be max. 0.1 MPa (1 bar) when the bottle pressure is 3
MPa (30 bar).
It is essential that the instrument air pressure, feeding to some critical control instrumentation,
is not allowed to fall below the nominal pressure stated in chapter "Compressed air system"
due to pressure drop in the pipeline.
5.2

Trace heating

The following pipes shall be equipped with trace heating (steam, thermal oil or electrical). It
shall be possible to shut off the trace heating.
● All heavy fuel pipes
● All leak fuel and filter flushing pipes carrying heavy fuel
5.3

Pressure class

The pressure class of the piping should be higher than or equal to the design pressure, which
should be higher than or equal to the highest operating (working) pressure. The highest
operating (working) pressure is equal to the setting of the safety valve in a system.
5-2
Recommended maximum velocities on pump delivery side for guidance
Pipe material
Stainless steel
Stainless steel / Carbon
steel
Black steel
Black steel
Black steel
Galvanized steel
Aluminum brass
10/90 copper-nickel-iron
70/30 copper-nickel
Rubber lined pipes
The diameter of gas fuel piping depends only on the allowed pressure loss in the
piping, which has to be calculated project specifically.
Wärtsilä 31DF Product Guide
Max velocity [m/s]
3
20
1.0
1.5
2.5
2.5
2.5
3.0
4.5
4.5
NOTE
DBAE248994