2. Operating Ranges
2.4
Low air temperature
In standard conditions the following minimum inlet air temperatures apply:
Gas mode:
● Low load + 5ºC
● High load -10ºC
Diesel mode:
● Starting + 5ºC
● Idling - 5ºC
● High load - 10ºC
For further guidelines, see chapter Combustion air system design.
2-10
Air Waste Gate (AWG) is needed when suction air temperature is below +5°C.
Wärtsilä 31DF Product Guide
NOTE