Download Print this page

Specifications; Operation - Ryobi LSL-100 Owner's Operating Manual

Advertisement

THANK YOU FOR BUYING A RYOBI PRODUCT.
To ensure your safety and satisfaction, carefully read through
this OWNER'S MANUAL before using the product.
General Safety Rules
All instructions must be read and observed in order to work safely
with the measuring tool. Never make warning signs on the
measuring tool unrecognizable.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
AND INCLUDE THEM WITH THE MEASURING TOOL WHEN
GIVING IT TO A THIRD PARTY.
Caution!
The use of other operating or adjusting equipment or the
application of other processing methods than those mentioned here
can lead to dangerous radiation exposure.
The measuring tool is provided with a warning label.
If the text of the warning label is not in your national language,
stick the provided warning label in your national language over
it before operating for the first time.
Do not direct the laser beam at persons or animals
and do not stare into the direct or reflected laser
beam yourself, not even from a distance. You could
blind somebody, cause accidents or damage your
eyes.
If laser radiation strikes your eye, you must deliberately close
your eyes and immediately turn your head away from the
beam.
Do not use the laser viewing glasses as safety goggles or
in traffic. The laser viewing glasses are used for improved
visualisation of the laser beam, but they do not protect against
laser radiation.
Do not make any modifications to the laser equipment.
Have the measuring tool repaired only through qualified
specialists using original spare parts. This ensures that the
safety of the measuring tool is maintained.
Do not allow children to use the laser measuring tool
without supervision. They could unintentionally blind other
persons or themselves.
Do not operate the measuring tool in explosive
environments, such as in the presence of flammable
liquids, gases or dusts. Sparks can be created in the
measuring tool which may ignite the dust or fumes.
APPLICATIONS
The measuring tool is intended for determining and indicating
exact horizontal and vertical lines. It is also suitable for checking
plumb lines and horizontal partitions or surfaces.
The tool is suitable exclusively for operation in enclosed/interior
working sites.
DESCRIPTION
1. On/ Off slide switch with operating-mode selector
2. Aluminium base
3. Spirit level for vertical alignment
4. Spirit level for horizontal alignment
5. Laser line aperture
6. Laser point aperture
7. Reference point
8. Magnet
9. Battery lid
10. Wall mount base
11. Reference surface for laser liner
12. Reference surface for laser pointer
13. Adjusting screw
14. ¼'' tripod mounting hole

SPECIFICATIONS

Working range ......................................... Line:3m, Point:20m
Laser accuracy ........................... Line:1mm/m, Point:0.5mm/m
Leveling accuracy .....................................................1mm/m
Operating temperature ...................................... -10 °C~40 °C
Laser class ..................................................................... 2
Laser type ........................... Line:635nm, Point:650nm, <1mW
Batteries ............................................. 2 x 1.5 V LR03 (AAA)
Estimated battery life ........................................ approx. <15hrs.
Net weight ............................................................... 0.11kg
INSERTING/REPLACING BATTERIES (Fig. 1)
Using alkaline batteries is recommended for operation of the
measuring tool.
Lesser measurements are possible if using 1.2V rechargeable
batteries.
1. Press the latch and remove the battery lid (9).
2. Insert 2pcs new battery according to the polarity indicators in
the battery compartment. Be sure the polarity (+/-) is correct.
3. Close the battery lid and lock it securely in place.
When inserting, pay attention to the correct polarity according
to the representation on the inside of the battery compartment.
Always replace all batteries at the same time. Do not use
different brands or types of batteries together.
Remove the batteries/rechargeable batteries from the
measuring tool when not using it for longer periods.
When storing for longer periods, the batteries can corrode and
self-discharge.

OPERATION

INITIAL OPERATION
Do not leave the switched-on measuring tool unattended
and switch the measuring tool off after use. Other persons
could be blinded by the laser beam.
Protect the measuring tool against moisture and direct
sun light.