Table of Contents

Advertisement

EQ33 Installation and service

9.10 Specifications

General data
Power supply: 12 and 24 V DC (10-32 V DC max) 8-16 watt
Power cable:
Power/NMEA cable, 2 m (153-6070-002)
Dimensions:
H:144 mm (5.8") W:252 mm (10") D:70 mm (2.8")
Weight:
1.5 kg (3.0 lbs)
Environment: -10 to +50°C, IEC 60945, waterproof USC 46 CFR and IP55
Housing:
Casted aluminum back, polycarbonate front
Display:
TFT color, power backlight: 5.7" 320x240 pixels, or .....
STN transflective monochrome 6" 320x340 pixels
Presentation:
4 pages. Manual, dedicated and remote switch, and automatic
sequencing.
Interfacing:
1 port in/out NMEA 0183
1 port NMEA 2000 (optional)
Alarm - signal output 5 V 50 mA
Fuse:
4.0A slow
Echosounder section
Frequencies:
50 or 200 kHz, selectable
Transmit power:600 watt RMS (4,800 W PP)
Impedance:
175 / 425 ohms
Display ranges: 5 to 1000 m in 21 steps, manual and auto mode
Detection
ranges:
Frequency
50 kHz
200 kHz
Pulse length:
Short, medium, long and auto
Transmission
rate:
Max. 10 pings per second
Alarms:
Fish, max. and min. depth
Zoom mode:
Bottom and VRM expansion, 6 to 50 meters, feet or fathoms
Event marker: At current ping and depth memory
Picture speed: True distance or time, high, medium, low, and freeze
Noise filter:
User selectable on/off
Echo pre-
sentation:
A-scope and white line discrimination
Temperature:
Sensor or NMEA
Speed:
Sensor or NMEA
Beam
Bottom
45°
800 m / 2,400 ft
15°
350 m / 1,050 ft
Chapter 9-15