Backup heat lockout temperature will enable auxiliary/sec-
ondary heating to be turned on when outdoor temperature is
much higher than indoor temperature, compressor might stop
operating under this circumstance.
Line Set Length Range
(feet)
0 to 100
100 to 200
In order to access temperature, the compressor lockout and
the backup heat lockout, press MENU and scroll down to
press INSTALLER OPTIONS. Enter the date code (password)
when prompted. Choose VIEW / EDIT CURRENT SETUP and
COMPRESSOR LOCKOUT / BALANCE POINT will be under
HEAT / COOL CONTROL OPTIONS. For more information
please refer to COMFORTNET™ CTK04 Communicating Ther-
mostat SYSTEM INSTALLATION GUIDE.

BOOST MODE

BOOST MODE enables the system to operate at a higher com-
pressor speed than rated maximum compressor speed and
satisfy the structural load more effectively during higher
ambient outdoor conditions. BOOST MODE is initiated by
an outdoor temperature sensor located in the outdoor unit.
Please note that outdoor equipment operational sound lev-
els may increase while the equipment is running in BOOST
MODE. Disabling BOOST MODE will provide the quietest and
most efficient operation.
NOTE: BOOST MODE is applicable only for AVZC200**1AB
or later revision. BOOST MODE performance is most effec-
tive when paired with an electronic expansion valve enabled
indoor unit.
BOOST MODE is ON by default and is activated when the
outdoor temperature reaches 105°F. BOOST MODE can be
disabled and enabled and the activation temperature ad-
justed in the BOOST TEMP menu using the following proce-
dure:
1. On the CTK04 HOME screen, select MENU.
2. From the MENU screen, select COMFORTNET™ USER
MENU.
Compressor Lockout Temperature
(°F)
15
20
SATURATED SUCTION PRESSURE
TEMPERATURE CHART
SUCTION PRESSURE
R-410A
PSIG
50
52
54
56
58
60
62
10
64
11
66
13
68
14
70
15
72
16
74
17
76
19
78
20
80
21
85
24
90
26
95
29
100
31
110
36
120
41
130
45
140
49
150
53
160
56
170
60
16
SATURATED LIQUID PRESSURE
TEMPERATURE CHART
LIQUID PRESSURE
°F
PSIG
1
200
3
210
4
220
6
225
7
235
8
245
255
265
275
285
295
305
325
355
375
405
415
425
435
445
475
500
525
550
575
600
625
R-410A
°F
70
73
76
78
80
83
85
88
90
92
95
97
101
108
112
118
119
121
123
125
130
134
138
142
145
149
152