Fujitsu ASYA09KLWA Design & Technical Manual page 7

Wall mounted type
Table of Contents

Advertisement

Dimensions
(H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type
Energy efficiency class
Pdesign
SEER
SCOP
Annual energy consumption
Sound power level
Notes:
1) Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB
-Outdoor Temperature 35 °C(95°F) DB /24 °C(75.2°F) WB
-Interconnecting Piping Length 5m
- Level Difference of Zero.
2) Protective function might work when using it outside the operation range
3) Sound pressure level was measured in anechoic chamber, the sound level measured in actual installation conditions
might be higher than the specified values here.
4) Due to our policy of innovation some specifications may be changed without notification .
Net
mm
Gross
Net
kg
Gross
Liquid
mm (in)
Gass
Method
Material
Size
mm
°C
Cooling
%RH
Heating
°C
Cooling
Heating (Average)
Cooling
kW
Heating (Average)
Cooling
kWh/kWh
Heating (Average)
QCE
kWh/a
QHE (Average)
Cooling
dB (A)
Heating
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- 3 -
805x194x285
870x285x360
7.6
9.7
φ6.35 (φ1/4)
φ9.52 (φ3/8)
Flare
PE
φ16
17-32
80 or less
0-30
Wireless
A++
A+
2.6
2.1
6.2
4.0
147
735
53
54
-Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Interconnecting Piping Length 5 m
- Level Difference of Zero.
3.5
2.3
6.1
4.0
201
822
53
54.5
1. Specifications

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asya12klwaAoya09klwaAoya12klwa

Table of Contents