Recommended Test Equipment - HP AM-4380/U 5261A Technical Manual

Table of Contents

Advertisement

Instrument Type
Electronic Counter
DC Voltmeter
AC Voltmeter
RF Millivoltmeter
Oscillator
High Frequency
Signal Generator
Oscilloscope
Coaxial Cable
Extender Cable
Feed-through
Termination
DC Power Supply
TABLE 5-1. Recommended Test Equipment
Required
Characteristics
0 v to ± 25v;
10 M Ω input impedance;
1% accuracy
1 mv to 500 mv;
10 cps to 1 Mc;
2% accuracy
1 mv to 500 mv;
500 kc to 50 Mc:
3% accuracy
10 cps to 100 kc;
1 mv to 500 mv
100 kc to 50 Mc:
1 mv- to 500 mv
10 cps to 10 Mc;
5 mv/cm
Low Microphonics
50-pin connectors;
straight-through
connections
BNC to BNC;
50Ω
100 vdc
Use
Provide power
Troubleshooting
Troubleshooting
Circuit adjustment
Troubleshooting;
Circuit adjustment
Troubleshooting;
Circuit adjustment
Troubleshooting;
Circuit adjustment
Troubleshooting;
Troubleshooting:;
Circuit adjustment;
Operation
Permits operation
outside of counter
Troubleshooting:
Circuit adjustment
Performance Check
5-0
Model 5261A
Section V
Table 5-1
Instrument
Recommended
(hp) Model 5243L or
(hp) Model 5245L
(hp) Model 412A
(hp) Model 403B
(hp) Model 411A with
(hp) 11025A Probe
(formerly (hp) 411A-21E)
(hp) Model 200CD
(hp) Model 606A
(hp) Model 175A with
(hp) Model 1752A
(hp) 10507A
(hp) 10506B
(hp) 10100A
(2 required)
(hp) 711A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AM-4380/U 5261A and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents