PowerWizard 1.0 & 2.0 Control Systems User Manual

4.1.2 PowerWizard 2.0 Menu Tree

MAIN MENU
ACTIVE EVENTS
EVENT LOG
ENGINE OVERVIEW
AC OVERVIEW
CONFIGURE
I/O STATUS
CONTROL
PREFERENCES
CONFIGURE
DIGITAL I/P
RELAY O/P
DIGITAL O/P
CONTROL
SPEED ADJUST
PROG CYCLE TIMER
PREFERENCES
CONTRAST
PRESSURE
TEMPERATURE
LANGUAGE
PowerWizard 2.0 Generating Set Control Menu Structure
ENG SPEED SENSOR
ERRATIC/LOST
ACTIVE
1
GENSET CONTROL
1
ENGINE CONTROL
0
GEN OVER CURRENT
WARNING
INACTIVE
0kPa
23 C
0 rpm
OR
STOPPED
AVG: 481 V
L-L
60.2Hz 0.82
LAGGING
OR
TOTAL kW
216
CURRENT LEVEL = 2
DROP TO MIN LEVEL
ENTER LEVEL 1 OR 2
SECURITY
ENTER LEVEL 3
SETPOINTS
CHANGE LEVEL 1 PWD
TIME DATE
CHANGE LEVEL 2 PWD
ENG OPERATE HRS
CHANGE SCADA PWA
SETPOINTS
CONTROL
ENGINE MON/PROTECT
EVENTS
GEN MON/PROTECT
I/O
NETWORK
OTHER
-2-4-----8
1---567-
1
ADJUST SPEED
0.0 Hz
1234567
OUTPUT1
01-0---
OUTPUT1
101----
*1
Figure 6: PowerWizard 2.0 Menu Tree
ESCAPE
3/17
*2 OR *3
OCC 1
KEY
*1. To adjust settings use:
1/3
*2
OCC 1
24.8V
2.1Hrs
*2. Scroll down to see all events. Events are listed in the following order, Present,
Active, Inactive. Only SHUTDOWN events can be reset; some events can be set
USE
as a SHUTDOWN. To reset an event, the control must be in STOP. All other
324V
events will become INACTIVE once the condition goes away.
48%
*3. To RESET: press ENTER to get to the details of the event and then ENTER
again.
*4. To get back to the MAIN MENU at any time, press
When unsure about your location on the screen, use ESCAPE Key and then refer to
this chart.
CONTROL
AUTOMATIC START/STOP
AVR DESIRED VOLTAGE
GOV DESIRED ENG SPD
ENG MONITOR/PROTECT
BATTERY VOLT MON
CRACK/START CTRS
ENG COOL TEMP MON
ENG OIL PRES MON
ENG SPEED MON
SERVICE MAINT INTERVAL
EVENTS
EVENT I/P FUNCTIONS
EVENT O/P FUNCTIONS
EVENT RESPONSE CFG
EVENT SYSTEM
GEN MON/PROTECT
GEN AC MONITOR
GEN AC PWR MONITOR
GEN OVER CURRENT
GEN OVER/UNDER FREQ
GEN OVER/UNDER VOLT
I/O
DIGITAL INPUTS
DIGITAL OUTPUTS
RELAY OUTPUTS
SPARE ANNALOG INPUT
NETWORK
DATALINK - SCADA
*1
OTHER
DIGITAL SELECTORS
REDUCED PWR MODE
PROG TRIP POINTS
ENTER
KEY
1. UP and DOWN Keys to select the submenu.
2. Use ENTER Key and UP, DOWN, LEFT, RIGHT
Keys and then ENTER for the new settings to take effect.
*1
*1
EVENT O/P FUNCTIONS
EVENT INPUT #1
*1
EVENT INPUT #2
EVENT INPUT #3
EVENT INPUT #4
EVENT INPUT #5
EVENT INPUT #6
EVENTS O/P FUNCTION
*1
EVENT OUTPUT #1
EVENTS RESPONSE CFG
DIAGNOSTIC CONFIG
DIAGNOSTIC CONFIG
PRESSURES
ENG PROTECT CONFIG
TEMPERATURES
GEN PROTECT CONFIG
LEVELS
OTHER SYSTEM CONFIG
OTHERS
ENG PROTECT CONFIG
PRESSURES
TEMPERATURES
LEVELS
*1
OTHERS
WARNING AUTO RESET
*1
ENABLED STATUS
ENABLED
*1
DIGITAL INPUTS
INPUT #1
INPUT #2
INPUT #3
*1
INPUT #4
INPUT #5
INPUT #6
INPUT #7
INPUT #8
DIGITAL OUTPUTS
*1
OUTPUT #1
RELAY OUTPUTS
OUTPUT #1
OUTPUT #2
OUTPUT #3
*1
OUTPUT #4
OUTPUT #5
OUTPUT #6
OUTPUT #7
OUTPUT #8
DIGITAL SELECTORS
DIGITAL SELECTOR #1
DIGITAL SELECTOR #2
DIGITAL SELECTOR #3
*1
DIGITAL SELECTOR #4
DIGITAL SELECTOR #5
*1
DIGITAL SELECTOR #6
DIGITAL SELECTOR #7
PROG TRIP POINTS
*1
PROG TRIP FUNC #1
or
and
*1
*1
12