25. Click "OK" button.
26. Click the Setup
as shown below.
Figure 4-12
IP setup dialog box
Note: The IP Setup screen allows you to set the Secure Data Mode
Station's IP Addressing information. The Secure Data Mode Station must
have an IP address assigned to it if you wish to connect to it using the
Configurator tool, which makes use of SNMP to connect to the Secure
Data Mode Station.
27. Select "Specify an IP address" and type a specific IP address and
gateway IP address. Click OK button.
Note: Except for cable modem built-in APU, the CSU to operate as APU
mode is required to set a mandatory static IP address for the unit even
though it can be set in both static IP and DHCP setup. But, you can set
DHCP mode to the CSU (APU mode) so that it can retrieve its IP
address from a remote or local DHCP server.
Note: For DHCP client mode, select "1 Ethernet" as the interface which
is used to get DHCP IP address from DHCP Server.
Note: If you select the DHCP option, it is recommended (though not
required) that you set up your DHCP server to always provide the same
IP address to this Secure Data Mode Station system.
WLAN Cable Access Point 6220 CSU NTPM99CA Rel 2.0 Issue 5 Dec 2005
IP Setup button. The IP Setup screen is displayed,
71