Appendix to the operating instructions
Translation of the original instructions
Energy throughfeed DRRD-...-P..E..
For all available product documentation è www.festo.com/pk
Note
• Observe the warnings and instructions in the operating instructions for the
DRRD semi-rotary drive.
1
Control sections and connections
DRRD-...-P.. (pneumatic)
1
2
DRRD-...-P..E.. (pneumatic and electric)
1
5
3
1
Through-hole for mounting the
DRRD (2x)
2
Supply port P1 ... P8 (output)
3
Electrical output S1 ... S8 (socket)
4
Mounting interface for working
load (4x)
Fig. 1
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
8103851
2018-12a
[8103853]
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
5
4
2
6
5
Supply port P1 ... P8 (input)
6
Electrical input S1 ... S8 (plug)
7
Housing
2
Function and application
The energy throughfeed DRRD-...-P..E.. serves to permit the passage of com­
pressed air and electrical signals through the drive shaft of the DRRD semi-rotary
drive.
3
Installation
3.1 Installation, mechanical
• Affix the DRRD with two screws to holes 1 and with 2 centring sleeves to the
housing 7.
• Affix the working load with at least two screws positioned opposite one another
to the drive flange, and with centring sleeves to threads 4.
Tightening torques are shown in the table below.
1
English
7
Fig. 2
Size
Mounting of DRRD
Screw in 1
(direct mounting)
Tightening torque
Screw through 1
(through-fastening)
Tightening torque
Centring sleeve ZBH
7
Mounting of working load
Screw in 4
Tightening torque
Centring sleeve ZBH
Fig. 3
3.2 Installation, pneumatic
If using the energy throughfeed with pneumatic connections DRRD−...−P..:
• Connect tubes to pneumatic connections 2 and 5.
Corresponding port identifications are used to indicate which tube to fit to
which push-in fitting (tubing dimensions è Fig. 8).
2
7
5
Fig. 4
3.3 Installation, electric
Warning
Danger of short circuit! If one of the electrical inputs 6 is supplied with voltage,
there will be voltage at all electrical inputs, because the positive and negative
lines are connected together inside the component.
• Ensure that the electrical inputs 6 share a common voltage source.
Otherwise the DRRD may be irreparably damaged by large compensating
currents.
• Leave the cover caps on the unused plugs 6.
The plugs 6 on the side of the housing are not protected in any other way
against accidental contact.
16
20
25
32
35
M5
M5
M6
M8
M8
[Nm]
6
6
10
18
18
M4
M4
M5
M6
M6
[Nm]
3
3
6
10
10
[mm]
9
9
12
15
15
M4
M4
M5
M6
M6
[Nm]
3
3
6
10
10
[mm]
7
7
9
9
9
4
40
50
63
M10
M10
M12
30
30
55
M8
M8
M10
18
18
30
15
15
25
M6
M8
M10
10
20
40
9
12
15

Advertisement

loading

Summary of Contents for Festo DRRD-...-P..E Series

  • Page 1 ....... English For all available product documentation è www.festo.com/pk Fig. 2...
  • Page 2 Output 4 (plug 6) 4 (sockets 3) • Only use connection accessories with a straight plug Number of connections (Accessories è www.festo.com/catalogue) at electrical connections 3 Designation (A) S1;S2, S3;S4, S5;S6, S7;S8 S1;S2, S3;S4, S5;S6, S7;S8 and 6. If using the energy throughfeed with electrical connections DRRD−...−P..E..: •...

This manual is also suitable for:

Drrd-16-p2e2Drrd-25-p2e2Drrd-20-p2e2Drrd-32-p2e2Drrd-35-p2e2Drrd-40-p2e2 ... Show all