Appendix A Troubleshooting

Introduction

Troubleshooting Files

Resolve Automatic Check Errors
Spent Reagents Container is Full
Rehybridization Workflow
Custom Recipes and Recipe Folders
System Check
RAID Error Message
Configure System Settings
Introduction
For technical questions, visit the NextSeq 500 support pages on the Illumina website. The support pages
provide access to documentation, downloads, and frequently asked questions.
Log in to your MyIllumina account for access to support bulletins.
For run quality or performance problems, contact Illumina Technical Support. See
page
50.
Consider sharing a link to the run summary in BaseSpace with Illumina Technical Support to facilitate
troubleshooting.
Troubleshooting Files
An Illumina Technical Support representative might request copies of run-specific or scan-specific files to
troubleshoot issues. Typically, the following files are used for troubleshooting.
Key File
Run information file
(RunInfo.xml)
Run parameters file
(RunParameters.xml)
RTA configuration file
(RTAConfiguration.xml)
InterOp files (*.bin)
Log files
Error log files
(*ErrorLog*.txt)
Global log files
(*GlobalLog*.tsv)
Lane log files
(*LaneLog*.txt)
Document # 15046563 v04
For Research Use Only. Not for use in diagnostic procedures.
Folder
Description
Root folder
Contains the following information:
• Run name
• Number of cycles in the run
• Number of cycles in each read
• Whether the read is an indexed read
• Number of swaths and tiles on the flow cell
Root folder
Contains information about run parameters and run components.
Information includes the RFID, serial number, part number, and expiration
date.
Data\Intensities
Contains the RTA configuration settings for the run.
The RTAConfiguration.xml file is created at the beginning of the run.
InterOp
Binary reporting files used for Sequencing Analysis Viewer.
InterOp files are updated throughout the run.
Logs
Log files describe each step performed by the instrument for each cycle,
and list software and firmware versions used with the run. The file named
[InstrumentName]_CurrentHardware.csv lists the serial numbers of
instrument components.
RTA Logs
Log of RTA errors.
Error log files are updated whenever an error occurs.
RTA Logs
Log of all RTA events.
Global log files are updated throughout the run.
RTA Logs
Log RTA processing events.
Lane log files are updated throughout the run.
Technical Assistance on
29
29
30
31
31
33
33
35
35
29

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NextSeq 500 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF