TK-3301
Test Equipment Required for Alignment
Test Equipment
1.
Standard Signal Generator (SSG)
2.
RF Power Meter
3.
Deviation Meter
4.
Digital Volt Meter (DVM)
5.
Oscilloscope
6.
High Sensitivity
Frequency Counter
7.
DC Ammeter
8.
AF Volt Meter (AF VTVM)
9.
Audio Generator (AG)
10. Distortion Meter
11. Spectrum Analyzer
12. Tracking Generator
13. 8Ω Dummy Load
14. Regulated Power Supply
■ Antenna connector adapter
The antenna connector of this transceiver uses an SMA
terminal.
Use an antenna connector adapter [SMA(f) – BNC(f) or
SMA(f) – N(f)] for adjustment. (The adapter is not provided
as an option, so buy a commercially-available one.)
■ Repair Jig (Chassis)
Use jig (part No.: A10-4125-03) for repairing the transceiv-
er. Place the TX-RX unit on the jig and fi t it with screws.
The jig facilitates the voltage check and protects the fi nal
amplifi er FET when the voltage on the fl ow side of the TX-
RX unit is checked during repairs.
■ Battery Jig (W05-1011-00)
Connect the power cable properly between the battery
jig installed in the transceiver and the power supply, and
be sure output voltage and the power supply polarity prior
to switching the power supply ON, otherwise over voltage
and reverse connection may damage the transceiver, or the
power supply or both.
20

ADJUSTMENT

Frequency Range
Modulation
Output
Input Impedance
Operation Frequency
Measurement Range
Frequency Range
Measuring Range
Input Impedance
Frequency Range
Frequency Stability
Frequency Range
Voltage Range
Frequency Range
Output
Capability
Input Level
Measuring Range
Center frequency
Output Voltage
Note: When using the battery jig, you must measure the
voltage at the terminals of the battery jig. Otherwise, a
slight voltage drop may occur within the power cable, be-
tween the power supply and the battery jig, especially while
the transceiver transmits.
Major Specifi cations
Operational frequency range of the transceiver
Frequency modulation and external modulation
–127dBm/0.1µV to greater than –47dBm/1mV
50Ω
Operational frequency range of the transceiver
Vicinity of 10W
Operational frequency range of the transceiver
10mV to 10V DC
High input impedance for minimum circuit loading
DC through 30MHz
10Hz to 1000MHz
0.2ppm or less
5A
50Hz to 10kHz
1mV to 10V
50Hz to 5kHz or more
0 to 1V
3% or less at 1kHz
50mV to 10Vrms
DC to 1GHz or more
50kHz to 600MHz
100mV or more
Approx. 8Ω, 3W
5V to 10V, approx. 3A
Useful if ammeter equipped
Schematic diagram
S
+
+
+ Terminal (Red)
– Terminal (Black)
–Terminal
(Black)
Power
Power
cable
supply
+Terminal
(Red)