Complete system setup and configuration | Stage 4
Cable and configure your client
1
micro USB console cable
Connect the console cable to the client and
1
the console port on the controller module.
Ethernet cable
Connect the client to the switch
2
on the management subnet:
a. Give the client a TCP/IP address
on the management subnet.
b. Set the console port on the client
to 115,200 baud with N-8-1 and flow
AC
control off.
2
If your system has one or more drive shelves, set the shelf IDs:
1. Power on the drive shelf, and then remove the end cap on the left of the shelf.
2. Press and hold the orange button until the first digit blinks, and then press the
button to advance the first digit (0-9) to the desired number. The first digit
continues to blink.
3. Press and hold the button until the second digit blinks, and then press the button
to advance the second digit (0-9) to the desired number. The first digit stops blinking,
and the second digit continues to blink. Each expansion shelf requires a unique shelf ID.
4. Press and hold the button until the second digit stops blinking, and then replace
the end cap on the shelf.
5. Wait about 10 seconds for both digits to start blinking again and for the LED to
illuminate, and then power-cycle the drive shelf to make the shelf ID take effect.
6. Repeat these steps for any remaining drive shelves.
Turn on the power
3
switches to both nodes
Configure your system using the Application Setup Wizard
4
SAN or NAS optimized system:
Log into System Manager, as described on the back of your system, and then complete the storage provisioning wizards
found under Applications in System Manager.
All other systems:
1. Assign an initial node management IP address to one of the
nodes If you have DHCP configured on your management
network, record the IP address assigned to the new controllers.
Otherwise,
a. Open a console session using PuTTY, a terminal server,
or the equivalent for your environment.
b. Enter the node management IP address when prompted.
HELPFUL LINKS
Lenovo Data Center Support Web site (worldwide):
http://datacentersupport.lenovo.com
Lenovo Data Center Support Web site (China):
http://support.lenovo.com.cn/EsWeb/
AC
Management subnet
1
2
B
2. Use System Manager Guided Setup to configure
your cluster.
a. Point your browser to the address you
assigned in step 1:
https://x.x.x.x.
b. Enter the data from your Cluster Configuration
Worksheet.
First Edition (September 2018)
© Copyright Lenovo 2018.
LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to
a General Services Administration (GSA) contract, use, reproduction, or disclosure is
subject to restrictions set forth in Contract No. GS-35F-05925.
LENOVO is a trademark of Lenovo.
Microsoft and Windows are trademarks of the Microsoft group of companies.
All other trademarks are the property of their respective owners.
© 2018 Lenovo.
DM3000x or DM5000x system
AC
1
2
Client
1
2
AC
Shelf ID
change
button
Shelf ID
A
change
button
B
1
A
2
1
2
2U12
2U24