Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards for design, manufacture, and intended use of the meter. LCR Research assumes no liability for the customer’s failure to comply with these requirements.
This chapter provides the basic operation procedures and describes names and functions on the display. Product Introduction LCR Elite2 (“the meter”) is a portable impedance measuring device for incoming inspection of components, quality control, and laboratory use. It is capable of measuring resistance, capacitance or inductance with 4 test frequencies (100Hz, 120Hz, 1kHz and 10kHz).
USB port using a standard micro-B USB cable or, by using a USB power adapter. The USB power adapter should have output voltage 5V +/- 5% with output current 100mA or greater. The USB power adapter is available separately. User Manual - LCR Elite2 - ver 1.3...
Rechargeable batteries have a limited number of charge cycles and may eventually need to be replaced. The meter battery isn’t user replaceable; it can be replaced only by a LCR Research Authorized Service Provider. User Manual - LCR Elite2 - ver 1.3...
Test frequency at 100Hz Page 15 120HZ Test frequency at 120Hz Page 15 1KHZ Test frequency at 1kHz Page 15 10KHZ Test frequency at 10kHz Page 15 Battery capacity indicator Page 3 User Manual - LCR Elite2 - ver 1.3...
2. Wipe the tips with a clean swab dipped in alcohol. 3. Wipe the case with a damp cloth and mild detergent. NOTE Do not use abrasives or solvents when cleaning the meter. User Manual - LCR Elite2 - ver 1.3...
Setting Up Menus This chapter describes how to set up menu items and parameters. Menu Structure Figure 2-1: Menu Structure Flowchart User Manual - LCR Elite2 - ver 1.3...
Once Autoset is selected, the meter resets the following parameters to default: Measurement: • o LCR: Auto o Secondary Parameters: Rs/Rp Test Parameters: • o Test Frequency: Auto o Circuit Mode: Auto User Manual - LCR Elite2 - ver 1.3...
Figure 2-5: Start Short Calibration 2. Once the navigation button is pressed, Figure 2-6 shows on the display indicating short calibration is in progress. Figure 2-6: Calibration in Progress User Manual - LCR Elite2 - ver 1.3...
Page 15
It can compensate for the parasitic capacitance most accurately. (4) After the battery is completely dead or hardware reset is performed, all the self-calibration data will be removed. Please perform self-calibration again if necessary. User Manual - LCR Elite2 - ver 1.3...
Auto: the meter automatically identifies the component under test (L, C or R). • R: measure resistance. • L: measure inductance. • C: measure capacitance. • Exit: Return to the measurement display. • Figure 2-13: LCR Menu User Manual - LCR Elite2 - ver 1.3...
Auto: set to auto circuit mode. Series or parallel circuit mode will be automatically identified. • Series: set to series circuit mode. • Parallel: set to parallel circuit mode. • Exit: Return to the measurement display. • Figure 2-16: Circuit Mode Menu User Manual - LCR Elite2 - ver 1.3...
LCR measurement includes auto mode (Auto), resistance measurement (R), inductance measurement (L), and capacitance measurement (C). Figure 3-1 shows a typical display in LCR measurement. It shows test frequency and test voltage on the top. The primary display is in the middle showing component type and measurement result. The secondary parameter reading is shown underneath the primary display.
(2) The autoset option in main menu can be used to reset the meter to the default mode (auto mode with auto testing frequency and auto circuit mode). Please refer page 7: Autoset to know which settings will be reset when autoset is selected. User Manual - LCR Elite2 - ver 1.3...
Test frequency (double click the navigation button to switch) Secondary parameter Circuit mode Component type and measurement result (single click the navigation button to switch) Battery Indicator Figure 3-6: Display of C measurement User Manual - LCR Elite2 - ver 1.3...
Table 3-9 Auto Mode Series/Parallel Rules Range of Component Under Test Circuit Mode Selected in Auto Mode C < 400 pF Parallel Circuit Mode C >= 400 pF Series Circuit Mode Always Series Circuit Mode User Manual - LCR Elite2 - ver 1.3...
The Aegis Technology is our patent pending solution that automatically protect the meter from being damaged by energized components. The traditional LCR meters have a common vulnerability to high voltage and current from the component they are measuring. In many cases, the component under testing can have stored energy, for example a charged capacitor or a powered on board.
EN61000-4-4: Burst EN61000-4-5: Surge EN61000-4-6: Conducted RF EN61000-4-11: Voltage Dips EN61000-4-11: Short Interruptions Calibration Cycle 1 Year (Recommended) NOTE Battery life varies by use, configuration, and many other factors. Actual results may vary. User Manual - LCR Elite2 - ver 1.3...
The measurements are performed with necessary open and short calibration done prior to verifying the • meter’s accuracy. Accuracy applies when Dx (measured D value) ≦ 0.1. When Dx > 0.1, accuracy is specified as: • (AZ + Offset) * √(1 + Dx User Manual - LCR Elite2 - ver 1.3...
0.001mF 0.7% + 0.005mF 0.7% + 0.005mF NOTE The accuracy for the ceramic capacitor will be influenced depending on the dielectric constant (K) of the material used to make the ceramic capacitor. User Manual - LCR Elite2 - ver 1.3...