5.3.2

Sampling method

The sample is taken by a vertical move of the bottle inside the fluid.
The bottle is linked with a graduated tape to monitor the bottle location.
For complete explanation of sampling procedures, please refer to §6 "Operation".
Important note: to avoid contamination of the sample taken by the sampler itself, check and clean
the unit and the bottle prior to use. Clean the unit with an appropriate cleaner without impacting the
unit or contamination risk of the next sample.
5.3.3

Liquid transfer

To transfer the fluid, no additional equipment is necessary. Just remove the sampling bottle
through bottom of Sampler and pour its content into an appropriated laboratory bottle.