Connect The Components; Troubleshooting - Kohler K-175 Homeowner's Manual

Bath media module
Hide thumbs Also See for K-175:
Table of Contents

Advertisement

JOBNAME: No Job Name PAGE: 6 SESS: 3 OUTPUT: Thu Jul 17 13:54:55 2008
Low Voltage
Access Cover
Indicator Light
High Voltage
Access Cover

1. Connect the Components

CAUTION: Risk of electric shock or product damage. Make sure the power cord for the media
module is unplugged or the power supply is turned off before removing the access covers.
Note: For wireless applications an Ethernet connection is not needed.
Remove the low voltage access cover.
Remove the grommets in the locations where the cables will be installed. Refer to the "Connection
Key."
Gently press each connection until it snaps together.
Slide the cable grommet into the slot with the male end up. Verify the grommet is properly seated.
Reinstall the access covers. Do not overtighten.
Plug the power cord into the outlet, or for hard-wire options, turn on the power. Verify that the
indicator light turns on and pulses.
Test each component to ensure proper functionality. Refer to the Installation and Homeowner
Guides packed with each of the individual components for additional information.

Troubleshooting

CAUTION: Risk of personal injury. The valve (if installed) may contain hot water; be careful when
draining any residual water.
IMPORTANT! Turn off the power and water supply to all components before performing any
maintenance.
1093174-5-B
Male End
Install grommets
flush with media box.
Grommet
Make sure power cord is unplugged
before opening access covers.
6
Slide grommet into slot with
male end up.
Kohler Co.