■ Install an earth leakage breaker depending on the
installation place.
If an earth leakage breaker is not installed, it could cause
electric shock.
■ Perform the drainage/piping work securely accord-
ing to the installation manual.
If there is defect in the drainage/piping work, water could
drop from the unit, soaking and damaging household
goods.
the outdoor unit.
This could cause injury.

1-2. SELECTING THE INSTALLATION LOCATION

INDOOR UNIT
the period following unpacking to before use.
device.
make the infrared remote control operate the air conditioner normally. The heat from the
lights may cause deformation or the ultraviolet may cause deterioration.
REMOTE CONTROLLER
controller are surely received by the indoor unit from that position ('beep' or 'beep beep'
receiving tone sounds). After that, attach remote controller holder to a pillar or wall and
install wireless remote controller.
Note:
remote controller may not be received.

1-3. SPECIFICATIONS

Model
Indoor unit
Outdoor unit
*1 Connect to the power switch which has a gap of 3 mm or more when open to interrupt the source power phase.
(When the power switch is shut off, it must interrupt all phases.)
*2 Use wires in conformity with design 60245 IEC 57.
*3 Use wires in conformity with design AS/NZS 5000.2.
*5 Use a copper pipe or a copper-alloy seamless pipe.
*7 Refrigerant pipe bending radius must be 100 mm or more.
■ Do not install the outdoor unit where small animals
may live.
If small animals enter and touch the electric parts inside
the unit, it could cause a malfunction, smoke emission,
clean.
■ Do not operate the air conditioner during interior
well after such work is performed. Otherwise, it may cause
volatile elements to adhere inside the air conditioner,
resulting in water leakage or scattering of dew.
Power supply *1
Rated
Frequency
Power supply *2
Voltage
capacity
10 A
230 V
50/60 Hz
16 A
CAUTION
(Could lead to serious injury in particular environments when operated incorrectly.)
OUTDOOR UNIT
defrosting, the defrosting time will be longer.
vibration.
conditioner may interfere with radio or TV reception in areas where reception is weak.
Note:
It is advisable to make a piping loop near outdoor unit so as to reduce vibration transmit-
ted from there.
Note:
When operating the air conditioner in low outside temperature, be sure to follow the
instructions described below.
directly to wind.
wall.
side of the outdoor unit.
Avoid the following places for installation where air conditioner trouble is liable to occur.
and factories, in which the properties of plastic could be changed and damaged).
formaldehyde, etc., which may cause chemical cracking.
Indoor/outdoor
connecting wire *2
transmission cable *3
3-core
1.0 mm²
4-core
1.0 mm²
3-core
2.0 mm²
■ To prevent damage from static electricity, touch
a nearby metal body to discharge static electric-
ity from yourself before touching the indoor unit
equipped with the Wi-Fi interface.
Static electricity from the human body may damage the
Wi-Fi interface unit.
■ Do not use the indoor unit equipped with the Wi-Fi
interface nearby other wireless devices, micro-
waves, cordless phones, or facsimiles.
It can cause malfunctions.
Pipe size
(thickness *4, *5)
Gas / Liquid
ø9.52 / 6.35 mm
(0.8 mm)
0.5 - 1.5 mm
2
ø12.7 / 6.35 mm
(0.8 mm)
Pipe length and height difference
Model
AP25/35/42
Max. pipe length
Max. height difference
Max. number of bends *6, *7
Refrigerant adjustment A *8
Insulation thickness *9, *10
Maximum amount
of refrigerant
charge *8
900 g
1100 g
AP50
20 m
12 m
10
20 g/m
8 mm