Packing List The following items should be included: Universal Tip Cleaner ......... 1 unit CLMU-PA Non-Metal Brushes ..... 1 unit Non-Metal Brushes Ref. CLMU-P1 Ref. CLMU-PA Brushes already installed inside the cleaner AC Adapter ............ 1 unit Manual ............1 unit Ref.
Page 3
w w w.jbctools.com Features Switch panel Sensors window Splashguard Window Locking tab USB-B connector Feet for vertical Power cord ESD safe access socket connector 3 3 3...
If excessive pressure is applied with the tool against any of the brushes, the cleaner stops automatically in order to protect the motors. Putting the tool out of the sensor detection area automatically reactivates the cleaner. The CLMU-PA is automatically switched off if the splashguard is opened during operation. 4 4 4...
w w w.jbctools.com Brush replacement 1. Pull the locking tab to open the 2. Pull the used up brushes out of the splashguard. cleaner by pressing its two opposite buttons. To replace the brushes just push them without pressing the buttons. Collection tray Remove the solder collection tray for disposal of solder waste.
Page 6
Brushes range CLMU-A Metal Brushes CLMU-A Metal Brushes (Black core) (Blue core) Ref. CLMU-A8 Ref. CLMU-A7 Core Material CLMU-A Non-Metal Brushes CLMU-A Non-Metal Brushes (Black core) (Blue core) Ref. CLMU-P1 Ref. CLMU-P7 When changing Brushes, see the table below for the different brush types. CLMU-A8 CLMU-A7 CLMU-P1...
- Check periodically that the sensors window is clean. Use a cotton bud with alcohol to clean it. - Maintain the brushes and the solder collection tray clean. - Replace any defective or damaged piece. Use original JBC spare parts only. - Repairs should be performed only by a JBC authorized technical service.
Update the cleaner software via USB connection: USB AB Cable Updater JBC Manager www.jbctools.com/manager.html Manage and monitor as many stations as your PC can handle by using the JBC Manager. You can export data to another PC. any JBC station USB AB Cable...
Page 9
w w w.jbctools.com Safety It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. - Do not use the appliance for any purpose other than tip cleaning. It is not a tool stand. - The AC Adapter power supply must be plugged into approved bases. - Do not leave the appliance unattended when it is running.
- ESD safe connector Complies with CE standards. ESD protected housing “skin effect”. Warranty JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear due to use or mis-use.
Need help?