Instructions for the Installer

12. INSTALLING THE APPLIANCE

12.1 Electrical connection
The nameplate with the technical data, serial number and mark is in a
visible position on the oven door frame.
The nameplate must never be removed.
The appliance must be connected to earth in compliance with electrical
system safety regulations.
If a permanent connection is used, the appliance's power supply line must
be fitted with an omnipolar breaking device with contact gap of at least 3
mm, located in an easily accessible position close to the appliance itself.
If a socket and plug connection is used, check that they are of the same
type. Do not use reducers, adapters or junctions since they may cause
overheating or burns.
Operation at 220-240 V~: use a
2
type H05RR-F (3 x 1.5 mm
) or
2
type H05V2V2-F (3 x 1.5 mm
)
three-wire cable.
The earth wire (yellow-green)
must be at least 20 mm longer
than the other wires at the end
for connection to the appliance.
If the power suppl y lead has to be replaced, remove the rear casing by
undoing the screws as shown below. The power lead gauge must be at
2
least 1.5 mm
(3 X 1.5 cable) and it must withstand temperatures up to
90°C (H05V2V2-F). Make sure that the cables follow the best possible
route and use band clamps to fix them at the side of the cabinet, to avoid
any contact with the oven.