Install Range Hood Blower Motor - KitchenAid UXB1200DYS Installation Instructions Manual

600 cfm and 1200 cfm internal blowers for range hoods
Table of Contents

Advertisement

Available languages

Available languages

4. Install the 6 mm nuts to the outside top or outside back
(alternate location on some models) of the range hood at the
proper location for the selected motor system.
Two 6 mm nuts are required for the single motor system.
Clip nuts into the small square notches located at the left
and right end of the square vent opening.
Five 6 mm nuts are required for the dual motor system.
Clip nuts into the small square notches, one located in
the front of the square vent opening and the other four
located at the left and right ends of the square vent
opening.
A
A
A. Clip nut (6 mm) locations for dual motor assembly (quantity five)
B. Clip nut (6 mm) locations for single motor assembly (quantity two)
5. Mount range hood using the Installation Instructions that
came with your range hood model.
A
B

Install Range Hood Blower Motor

1. Install the range hood blower motor assembly inside the
range hood canopy with the wiring connection to the left for
the single motor system and to the front or top for the dual
motor system.
Single Blower Motor Assembly
A
A. Wiring connection
Dual Blower Motor Assembly
A. Wiring connection
A
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents