1200 cfm (34.0 m3/m) exterior blower
Table of Contents

Advertisement

Available languages

Available languages

KitchenAid
Installation Instructions and Use and Care Guide
IMPORTANT:
READ AND SAVE THESE INSTRUCTIONS.
The installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future
reference and for local electrical inspectors use.

Before you start...

Your safety and the safety of others
are very important.
We have provided many important
safety messages in this manual and on
your appliance. Always read and obey
all safety messages.
This is the safety alert
symbol.
This symbol alerts you to
potential hazards that can kill or hurt
you and others.
All safety messages will follow the
safety alert symbol and either the word
"DANGER" or "WARNING". These
words mean:
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE
THE FOLLOWING: Use this unit only
in the manner intended by the
manufacturer. If you have any
questions, contact the manufacturer.
Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a prominent warning
device, such as a tag, to the service
panel.
CAUTION: For General Ventilating Use
Only. Do Not Use To Exhaust
Hazardous or Explosive Materials and
Vapors.
IMPORTANT: Observe all governing
codes and ordinances.
Proper installation is your responsibility.
Make sure you have everything
1200 cfm (34.0 m
You can be killed or seriously
injured if you don't immediately
follow instructions.
You can be killed or seriously
injured if
instructions.
All safety messages will tell you what
the potential hazard is, tell you how to
reduce the chance of injury, and tell you
what can happen if the instructions are
not followed.
necessary for correct installation. It is
the responsibility of the installer to
comply with the clearances specified.
To avoid damage to motor bearings
and impellers, keep drywall spray,
construction dust, etc. away from the
exterior blower.
IMPORTANT
Before installing exterior mounted
blower, read the Installation Instructions
for the vent system that will be used in
conjunction with this exterior blower.
This fan is suitable for use with solid-
state speed controls.
25" (63.5 cm)
33-1/4"
(84.5 cm)
Model KPEU722M
®
3
/m) Exterior Blower
DANGER
WARNING
you don't follow
31-5/8"
(80.3 cm)
26-3/4"
(67.9 cm)
Electrical
requirements
IMPORTANT: Observe all governing
codes and ordinances.
It is the customer's responsibility:
• To contact a qualified electrical
installer.
• To assure that the electrical installation
is adequate and in conformance with
National Electrical Code, ANSI/NFPA
70 — latest edition*, or CSA
Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2
No.0-M91 - latest edition** and all local
codes and ordinances.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you
are not sure exterior blower is properly
grounded.
Do not have a fuse in the neutral or
ground circuit.
A.
A 120-volt, 60-Hz, AC-only supply
wired for 15 amp service is required.
B.
The blower motor must be
connected with copper wire only.
Copies of standards listed may be
obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
8-1/4"
(21.0 cm)
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid KPEU722M

  • Page 1: Before You Start

    Hazardous or Explosive Materials and Vapors. IMPORTANT: Observe all governing codes and ordinances. Proper installation is your responsibility. Make sure you have everything Model KPEU722M ® /m) Exterior Blower DANGER You can be killed or seriously injured if you don’t immediately follow instructions.
  • Page 2: Venting Requirements

    The blower motor must be connected to the vent system wiring as described in the vent system instructions for connecting the exterior blower motor wiring. Flexible armored or nonmetallic cable must be used. A 1/2" (12.7 cm) U.L./CSA-listed strain relief must be provided at each end of the power supply cable.
  • Page 3 Now start... WARNING Excessive Weight Hazard Use two or more people to move and install external blower. Failure to do so can result in back or other injury. Discard any cardboard packaging from the blower wheel. Attach the black plastic vent collar to the exterior blower using the four screws provided.
  • Page 4: Making Electrical And Vent Connections

    If you are installing external blower on a flat roof: 2 x 4 framing recommended 33-1/4" (84.5 cm) 7" (17.8 cm) 11" (27.9 cm) dia. hole discharge side of blower 2" 26-3/4" (5.1 cm) (67.9 cm) Locate the 11" (27.9 cm) dia. hole between rafters.
  • Page 5: Warranty

    This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state or province to province. Outside the 50 United States and Canada, this warranty does not apply. Contact your authorized KitchenAid dealer to determine if another warranty applies.
  • Page 6: Requesting Assistance Or Service In U.s.a

    1901 Minnesota Court Mississauga, Ontario L5N 3A7 Part No. 436001861/8285496 Pièce N° 436001861/8285496 © 2003 KitchenAid ® Registered trademark/™ trademark of KitchenAid, U.S.A., KitchenAid Canada licensee in Canada • Use and maintenance procedures • Accessory and repair parts sales •...
  • Page 7: Alimentation Électrique

    IMPORTANT : Respecter les dispositions de tous les codes et règlements en vigueur. C’est au propriétaire qu’incombe la responsabilité d’une installation correcte. Modèle KPEU722M ® DANGER Risque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions.
  • Page 8 Le moteur du ventilateur doit être raccordé au câblage d’alimentation selon les instructions fournies avec le système d’aspiration. On doit utiliser un câble flexible blindé ou à gaine non métallique. On doit installer un serre-câble de 1/2 po (homologation U.L./CSA) à chaque extrémité...
  • Page 9 Commencement... AVERTISSEMENT Risque de poids excessif Utiliser deux ou plus de personnes pour déplacer et installer de la hotte. Le non-respect de cette instruction peut causer une blessure au dos ou d’autre blessure. Retirer tout carton d’emballage de la turbine du ventilateur. Fixer la collerette de plastique noir sur le ventilateur extérieur avec les quatre vis fournies.
  • Page 10 Tracer un cercle de diamètre 27,9 cm (11 po) centré sur le trou de guidage – voir la FIGURE 2. Marquer le centre du trou de diamètre 3 cm (1-1/4 po) à percer pour le passage du câble électrique – voir la FIGURE 2. Découper les planches de platelage du toit sur le périmètre du cercle de diamètre 27,9 cm (11 po).
  • Page 11: Garantie

    G. Au Canada, frais de déplacement ou de transport pour les clients qui résident dans des régions éloignées. KITCHENAID ET KITCHENAID CANADA NE SONT PAS RESPONSABLES POUR LES DOMMAGES FORTUITS OU INDIRECTS. Certains États ou certaines provinces ne permettent pas l’exclusion ou la limitation des dommages fortuits ou indirects de sorte que cette exclusion ou limitation peut ne pas s’appliquer dans votre cas.
  • Page 12: Demande D'assistance Ou De Service Au Canada

    : Pièce N° 436001861/8285496 © 2003 KitchenAid ® Marque déposée /™ Marque de commerce de KitchenAid, U.S.A., KitchenAid porteur de licence au Canada • Procédés d’utilisation et d’entretien • Vente d’accessoires et de pièces de rechange • Assistance spécialisée aux clients (langue espagnole, malentendants, malvoyants, etc.)