Wilo -Rexa FIT V06DA-110/EAD1-2-T0015-540-P Installation And Operating Instructions Manual
Wilo -Rexa FIT V06DA-110/EAD1-2-T0015-540-P Installation And Operating Instructions Manual

Wilo -Rexa FIT V06DA-110/EAD1-2-T0015-540-P Installation And Operating Instructions Manual

Hide thumbs Also See for Wilo-Rexa FIT V06DA-110/EAD1-2-T0015-540-P:

Advertisement

Quick Links

Pioneering for You
Wilo-Rexa FIT
de Einbau- und Betriebsanleitung
en Installation and operating instructions
fr
Notice de montage et de mise en service
es
Instrucciones de instalación y funcionamiento
pt
Manual de Instalação e funcionamento
nl
Inbouw- en bedieningsvoorschriften
sv
Monterings- och skötselanvisning
fi
Asennus- ja käyttöohje
hr
Upute za ugradnju i uporabu
pl
Instrukcja montażu i obsługi
ru Инструкция по монтажу и эксплуатации
lt
Montavimo ir naudojimo instrukcija
ro Instrucţiuni de montaj şi exploatare
6063547 Ed03-10/2014 WH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wilo-Rexa FIT V06DA-110/EAD1-2-T0015-540-P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wilo Wilo-Rexa FIT V06DA-110/EAD1-2-T0015-540-P

  • Page 1 Pioneering for You Wilo-Rexa FIT de Einbau- und Betriebsanleitung en Installation and operating instructions Notice de montage et de mise en service Instrucciones de instalación y funcionamiento Manual de Instalação e funcionamento Inbouw- en bedieningsvoorschriften Monterings- och skötselanvisning Asennus- ja käyttöohje Upute za ugradnju i uporabu Instrukcja montażu i obsługi...
  • Page 2 Fig. 1 Fig. 3 S2 / S3 Fig. 2...
  • Page 3 Fig. 4 Fig. 5 M 1~ Fig. 6 Fig. 7/8 M 3~...
  • Page 5: Table Of Contents

    Dry-running protection 5.5. Electrical connection 5.6. Motor protection and activation types Commissioning 6.1. Electrical system 6.2. Rotation control 6.3. Level control 6.4. Commissioning 6.5. Safety rules during operation Decommissioning/disposal 7.1. Temporary decommissioning 7.2. Decommissioning for maintenance work or stor- 7.3. Removal 7.4. Return delivery/storage 7.5. Disposal Installation and operating instructions Wilo-Rexa FIT...
  • Page 6: Introduction

    This operating and maintenance manual has been copyrighted by the manufacturer. The operating In general, repairs should only be carried out by and maintenance manual is intended for use by Wilo customer service. installation, operating and maintenance person- nel. It contains technical regulations and drawings 1.5.6. Disclaimer which may not be reproduced or distributed,...
  • Page 7: Safety

    Furthermore, if such work is being carried out outdoors, it must be cancelled if the weather Instruction symbol, for example, wear protec- conditions worsen. tive clothing These instructions must be strictly observed. Non-observance can result in injury or substan- tial material damage. The safety symbols used conform to the gener- ally applicable directives and regulations, such as DIN and ANSI. Installation and operating instructions Wilo-Rexa FIT...
  • Page 8: Electrical Work

    • Pumps that have been operated in sewage water containing faeces and/or fluids that are hazardous to health must be decontaminated before being 2.4. Safety and monitoring devices used with other fluids. The pumps are equipped with a thermal winding monitor. The pump is switched off if the motor Clarification must be sought as to whether the gets too hot during operation. pump can be used at all with another fluid. WILO SE 10-2014 V05 DIN A4...
  • Page 9: Sound Pressure

    CAUTION: Wear ear defenders! According to applicable laws and regula- 3.2. Set-up tions, ear protection must be worn if the The Wilo-Rexa pumps are submersible sewage sound-pressure level is 85 dB(A) or more! pumps that can be operated vertically in sta- The end-user must make sure that this is...
  • Page 10: Operating Modes

    DN 65, PN 10 The pump can operate continuously at the rated load without exceeding the permissible temper- FIT …08-…: DN 80, PN 10 ature. Pressure connection: FIT …05-…: DN 50/Rp2, PN 10 3.3.2. Operating mode S2 (short-term operation) The maximum operating period is specified in FIT …06-…: DN 65/80, PN 10 minutes, e.g. S2-15. The pause must last until the FIT …08-…: DN 80/100, PN 10 machine temperature no longer differs from the temperature of the coolant by more than 2 K. WILO SE 10-2014 V05 DIN A4...
  • Page 11: Type Key

    1 minute before the control motor is switched back on again! • Level controls • Fixing accessories and chains 3.5. Type key • Switchgears, relays and plugs Wilo-Rexa Example: FIT V06DA-110/EAD1-2-T0015-540-P 4. Transport and storage Series Impeller shape 4.1. Delivery...
  • Page 12: Return Delivery

    5. Installation solids, dry, frost-free and, if necessary, de- contaminated. It must also be suitable for the In order to prevent damage to the product or seri- particular pump. ous injury during installation, the following points must be observed: • When working in sumps, a second person must be present for safety reasons. If there is a risk of WILO SE 10-2014 V05 DIN A4...
  • Page 13 • Details for "Non-immersed operating mode" • Please observe all regulations, rules and legal requirements for working with and underneath heavy suspended loads. Wear appropriate protec- tive clothing/equipment. • Please also observe the applicable national acci- dent prevention regulations and trade association safety provisions. Installation and operating instructions Wilo-Rexa FIT...
  • Page 14 RISK of pressure hose becoming separated! sures the minimum ground clearance and a secure Uncontrolled separation or movement of the footing if placed on a solid bearing surface. In this pressure hose can result in injuries. Secure the version, the pump can be positioned anywhere in pressure hose appropriately. Prevent buckling the operating space. If used in an operating space of the pressure hose. with a soft bearing surface, a hard base must be WILO SE 10-2014 V05 DIN A4...
  • Page 15: Dry-Running Protection

    • Have the electrical connections made by a qualified electrician. • Manual reset The motor is switched off when the water level Installing optional accessories, such as dry-run- falls below the minimum coverage level and ning protection or level controls. switched back on when a sufficient water level is Starting up the pump: about 2-4 h reached. • As described in the “Commissioning” section Installation and operating instructions Wilo-Rexa FIT...
  • Page 16: Electrical Connection

    Do not connect the The three-phase version can be executed as pump and consult Wilo customer service. follows: • with a float switch and CEE plug Insulation resistance of the motor winding •...
  • Page 17: Motor Protection And Activation Types

    • Operating mode • Minimum water submersion/max. immersion depth 5.6.1. Motor protection These general conditions must also be checked The minimum requirement for motors with a free cable end is a thermal relay/motor protection after a lengthy period without operation, and switch with temperature compensation, differ- any defects detected must be repaired! ential triggering and an anti-reactivation device Installation and operating instructions Wilo-Rexa FIT...
  • Page 18: Electrical System

    The direction of rotation must be checked with a rotating field tester by a local electrician. For the • Check switching points of level control and correct direction of rotation, a clockwise rotating dry-running protection systems field must be available. • Check to ensure all accessories are properly The pump is not approved for operation with fitted a counter-clockwise rotating field! • The following points must also be checked for wet well installation: WILO SE 10-2014 V05 DIN A4...
  • Page 19: Safety Rules During Operation

    • Current consumption (permissible deviation between phases is a maximum of 5%) The system must be switched off and the pump • Voltage difference between the individual must be disconnected from the mains by an electrician and secured against being switched phases (max. 1%) on again without permission. Pumps with plugs • Switching frequency (see technical data) Installation and operating instructions Wilo-Rexa FIT...
  • Page 20: Removal

    Any other work and/or alterations to the construction must only be carried out by Wilo For return delivery and storage please also refer customer service. to the “Transport and storage” section! • When carrying out work in basins and/or tanks,...
  • Page 21: Operating Materials

    8.2.2. Intervals for harsh operating conditions • Operating materials should be collected in suit- Under harsh operating conditions, the specified able containers and disposed of properly. Always maintenance intervals must be shortened accord- wear appropriate protective clothing when per- ingly. In this case, contact Wilo customer service. forming maintenance and repair work. This must If using the pump under harsh conditions, we also recommend signing a maintenance contract. also be disposed of properly. Harsh operating conditions include: 8.1. Operating materials •...
  • Page 22: Maintenance Work

    Fig. 7.: Screw plugs power supply cable must be replaced. Screw plug The cables may only be replaced by Wilo customer service or an authorised or certified service workshop. The pump may only be start- Position the pump horizontally on a firm surface ed up again once the damage has been properly with the screw plug facing upward.
  • Page 23 Signs of wear Impeller blocked or slowed • Replace worn parts Defective motor bearing • Switch off the pump, secure it against being switched back on again and free the impeller • Contact the manufacturer Installation and operating instructions Wilo-Rexa FIT...
  • Page 24: Appendix

    Please note that you may be charged for some services provided by our customer service. For more details, please contact Wilo customer service. 10. Appendix 10.1. Spare parts Spare parts can be ordered from Wilo customer service. To avoid return queries and incorrect or- ders, the serial and/or article number must always be supplied. Subject to change without prior notice! WILO SE 10-2014 V05 DIN A4...