WARNING: The following procedures should be done by professional authorized dealers only.
Users who like to Do-It-Yourself should bear their own risk. Sky-Watcher Telescope is not
responsible for the damages resulting from installation attempts.
For mounting a DOB Traditional, DOB Collapsible, or Newtonian reflector telescope tube OTA on a
SynScan Dob GOTO upgrade kit, user should replace one of the side bearings on the tube with a
bracket that comes with the upgrade kit.
Please read the following instructions on how to best finish the job.
1. Remove the side bearing which is on the side of the focuser.
If the telescope is a traditional solid tube type, we recommend you to remove the primary
mirror from the tube first. Then you can remove the side bearing through the bottom of the
tube. To remove the primary mirror, simply remove the 6 screws around the bottom of the
tube and keep the primary mirror at a safe place to avoid damaging the surface of the
mirror.
If your telescope is a collapsible type, there is no need to remove the primary mirror from
the tube.
Please keep the removed side bearing, screws, and washers in a safe place for future use.
2. Installing the mount bracket.
From the DOB SynScan (GoTo) Upgrade kit, locate the new mount bracket (shown in Figure
2). Install the new mount bracket at the same location as the removed side bearing. The two
horizontal mounting holes should fit into the holes on the tube.
Use two short flat head screws to fix the bracket onto the tube. Apply a washer between the
nut and wall of the tube. The telescope with the new bracket installed should look like
Figure 3.
How to use DOB SynScan (GoTo) Upgrade Kit
Figure 2
Figure 1 Dob Collapsible OTA
Figure 3
170611V2

Advertisement

loading

Summary of Contents for SKY-WATCHER DOB SynScan

  • Page 1 Please keep the removed side bearing, screws, and washers in a safe place for future use. 2. Installing the mount bracket. From the DOB SynScan (GoTo) Upgrade kit, locate the new mount bracket (shown in Figure 2). Install the new mount bracket at the same location as the removed side bearing. The two horizontal mounting holes should fit into the holes on the tube.
  • Page 2 3. Installing the extra mounting screws. If you would like to have the maximum stability, you should fix the bracket with two extra screws. You will need to drill two 6mm diameter holes on the tube. Mark the positions of the two extra holes on the tube (as shown in Figure 3), then remove the bracket to drill holes on the tube.