Starting And Operation - Kaindl WIG 4 Operating Instructions Manual

Electrode sharpening machine
Table of Contents

Advertisement

1.
Connect the dust exhaust of industrial vacuum cleaner with Filter type M to the pipe (7)
2.
Degrease the electrodes before grinding, best with spirit or similar.
3.
Adjust the top angle after opening the clamping lever (5), the number on the scale
corresponds to the top angle of the finished electrode
4.
Switch on the dust exhaust
5.
Select the diameter of the electrode with the adjustment slide (3)
6.
Turn on the machine with the main switch (1)
7.
Adjust the drive control with knob number (4) to the
requested diameter (see display)
8.
Tuck the electrode through the electrode guide with the
selected diameter of boring
9.
Turn the drive control (4) anticlockwise until the
electrode turns constantly
10. Finish the grinding operations, tear back the drive control (4)
and withdraw the electrode simultaneously
11. Switch of the machine with the main switch (1)
12. Switch off the dust exhaust
ATTENTION! By using the bushes (special accessory) let project the electrodes around
10 mm !
9
7
5
6
4
(1)
Main switch ON/OFF
(2)
Guide for electrodes
(3)
Adjustment slide for electrodes
(4)
Drive control
7.
START UP AND OPERATION
(5)
Top angle adjustment
(6)
Horizontal adjustment
(7)
Connection pipe for dust exhaust
(8)
Display: diameter of electrode
(9)
Carrying handle
7
1
2
3
8

Advertisement

Table of Contents
loading