Sloan OPTIMA Series Installation Instructions And Maintenance Manual

Sloan OPTIMA Series Installation Instructions And Maintenance Manual

Systems, sensor operated surface mounted electronic hand dryer

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS AND MAINTENANCE GUIDE
SENSOR OPERATED SURFACE MOUNTED ELECTRONIC HAND DRYER
Installation of the Sloan OPTIMA Series Electronic Hand Dryer makes
drying of hands totally "hands-free" providing the ultimate in sanitary
protection and automatic operation. There are no buttons to push. The
OPTIMA series electronic hand dryer uses fiber optic and adaptive
sensing technology to sense the user's presence and activate. When the
user's presence is no longer detected, the hand dryer automatically
stops.
Sloan Valve Company warrants its Electronic Hand Dryers to be made of first class materials, free from defects of material or workmanship under normal use and to
perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of five years from date
of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve
Company, at customer's cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental
costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company's products directly from Sloan Valve Company for purpose of
resale.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE
COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
OPTIMA™ SYSTEMS
The OPTIMA series electronic hand dryer is designed for easy
installation and maintenance, quiet and efficient operation, and years of
dependable, trouble-free service.
The following instructions will serve as a guide when installing the
OPTIMA Series electronic hand dryer. As always, good safety practices
and care are recommended when installing your new hand dryer. If
further assistance is required, contact your nearest Sloan
Representative office.
LIMITED WARRANTY
EHD l.l. — Rev. 2 (01/01)
Code No. 0816167
Model EHD 120
Sensor Operated Hand Dryer
120 VAC
Model EHD 208/240
Sensor Operated Hand Dryer
208 VAC or 240 VAC
Listed
Made in the U.S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPTIMA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Sloan OPTIMA Series

  • Page 1 During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty.
  • Page 2 PRIOR TO INSTALLATION ROUGH-IN — Figure 1 Prior to installing the Sloan OPTIMA Series Electronic Hand Dryer, determine the location where the dryer will be installed. Read the 7/8" (22 mm) DIA. HOLE FOR ELECTRICAL following paragraph entitled “Installation Precautions” and then refer to CONNECTION Table 1 and Figure 1 for recommended mounting heights.
  • Page 3 INSTALLATION LED INDICATOR HEATER BLOWER LIGHTS CONNECTION CONNECTION Step 1 — Mount Chassis to Wall (Figure 1) String electrical wires through Chassis Assembly and secure Chassis Assembly to wall using the recommended Fasteners listed in Table 2. Step 2 — Electrical Hook-Up (Figures 2, 3 and 4) Be certain that power is disconnected at the main power source.
  • Page 4 Note: Each power board has two (2) LED’s: a green power indicator and The OPTIMA Series electronic hand dryer is factory set to operate at a a red sensor indicator. Electrical power must be supplied to Hand Dryer range of 4 to 11 inches (102 to 279 mm).
  • Page 5 Exhaust Grille. 3. OPTIMA Sensor has failed; replace with Sensor/Power Board Replacement Kit. If further assistance is required, please contact the Sloan Valve 4. Power Board has failed; replace with Sensor/Power Board Company Installation Engineering Department at 1-888-SLOAN-14.
  • Page 6 Current EHD Hand Dryer Power Boards and OPTIMA 120 VAC EHD-12-A EHD-13-A EHD-1006-A (3366007) Fiber Optic Sensors will operate in older Sloan EHD Hand Dryers if the 1986 - 1991 208/240 VAC EHD-65-A EHD-13-A EHD-1007-A (3366008) following conditions are met:...