4.1.1
Rinse aid prime :
4.1.2
Detergent / Soap prime :
The detergent / soap pump system on these appliances is self
priming.
4.1.3
Chemical dosage :
Chemical doses are pre-set to the following nominal values,
however these values should be calibrated to suit individual sites
requirements
Pre-set values (in seconds)
H700, H750 & Duo 750
Adjustment of chemical dose is via the timer located under the top
panel of the appliance, the timer allows the following values to be
calibrated to suit the sites requirements
Page 6
Switch machine ON and allow to fill
Remove the lower front panel (do not
to touch any wire connections).
Depress and hold button located on
the chemical pump bracket.
To fully prime, this will take approx 1 ½
minutes.
Replace the front lower panel.
Machine sizes
Eco 1
Eco 2 & Duo 2
Eco 3 & Duo 3
H500 & Duo 500
Rinse aid
Cycle
Initial
5
50
5
70
5
140
5
50
5
90
Detergent
Cycle
10
10
10
10
10