3.3
Water connection :
The appliance comes with a water supply hose requiring a ¾" BSP male
threaded connection at the mains water supply, upon installation and
commissioning all water joints must be checked for leaks).
3.3.1
Water supply restrictions :
Water supply constraints must be adhered to :
3.3.2
Drainage systems
Appliances are available as either gravity drain or pumped drain, upon
installation the waste hose and stand pipe must be configured as shown within
this manual, also all installations must be with a running / 'P' trap to ensure
hygiene :
Drain pump machine
Page 4
Incoming water temperature
Supply water dynamic pressure
issue).
Ø40mm (Ø1 ½")
standpipe required
Standpipe must be
100 to 150mm (4" to
6") below the top of
the appliance.
The end of the
waste outlet hose
in the standpipe
must not be lower
than the bottom of
the door.
The waste outlet
hose must be a
loose fit within the
standpipe.
4° c minimum
55° c maximum
(air break machines, low water pressure is not an
0 to 2 bar
Rinse booster pump required
2 to 4 bar
No modifications required
4 to 6 bar
Flow restrictor required
6 bar plus
Pressure reducing valve required