6-14. EHST20C-MECR1.UK, EHST20D-MECR1.UK, EHST20D-MHCR1.UK, ERST20C-MECR1.UK, ERST20D-MECR1.UK
Immersion heater (1Ph3kW)(Option)
Power supply
to Immersion heater
~/N 230V 50Hz
L
N
(1)
(3)
ECB2
2 4
IHC
1
3
5
A1
2
4
6
A2
A B
IHT
IH
2
1 Symbols used in wiring diagram are,
: connector,
: terminal
block.
2 Indoor unit and outdoor unit
connecting wires have polarities,
make sure to match terminal
numbers (S1, S2, S3) for correct
wirings.
3. Since the outdoor unit side electric
wiring may change, be sure to
check the outdoor unit electric
wiring diagram for service.
Table 1 Signal Inputs
Name Terminal block Connector
Item
Room thermostat
IN1
TBI.1 13-14
1 input
Flow switch 1
IN2
TBI.1 11-12
input
Flow switch 2
IN3
TBI.1 9-10
input (Zone1)
Demand control
IN4
TBI.1 7-8
input
Outdoor thermo-
IN5
TBI.1 5-6
stat input *1
Room thermostat
IN6
TBI.1 3-4
2 input
Flow switch 3
IN7
TBI.1 1-2
input (Zone2)
Electric energy
IN8
TBI.3 1-2
meter 1
Electric energy
IN9
TBI.3 3-4
meter 2
IN10
TBI.3 5-6
Heat meter
IN1A TBI.3 12-14 CN1A Flow sensor
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the
heaters and related parts may be reduced.
*2. To turn on the boiler operation, use the main remote controller to select "Boiler" in
"External input setting" screen in the service menu.
Symbol
Name
TB1
Terminal block <Power supply, Outdoor unit>
ECB2
Earth leakage circuit breaker for immersion heater
MP1
Water circulation pump 1
(Space heating/cooling & DHW)
MP2
Water circulation pump 2
(Space heating/cooling for Zone1)(Local supply)
MP3
Water circulation pump 3
(Space heating/cooling for Zone2)(Local supply)
MP4
Water circulation pump 4 (DHW)
3WV
3-way valve
2WV2a
2-way valve (For Zone 1)(Local supply)
2WV2b
2-way valve (For Zone 2)(Local supply)
MXV
Mixing valve (Local supply)
IHT
Thermostat (fixed temp.) for immersion heater
IH
Immersion heater
IHC
Contactor for immersion heater
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
OCH570C
F1
CNPWM
(WH)
1
F2
3
3
CNP1
TBO.1
(WH)
X1
1
1
M
1~
2
MP1
3
M
X2
3
1~
M
2WV2b
1~
4
X3
MP2
5
M
1
1~
6
2
MP3
3
X14
1
4
M
1~
5
3
MP4
6
CNP4
(RD)
1
2
TBO.2
X5A
3
Close
1
4
M
N
2
1~
Open
5
X5B
MXV
6
3
X4
1
4
1
M
3
2
1~
5
5
3
3WV
6
CNV1
4
(WH)
5
6
TBO.3
7
X10
1
Signal output
8
(Boiler)
2
1
X11
3
1
Signal output
2
CNIH
(Error)
4
3
3
(OG)
X12
5
Signal output
4
(Defrost)
5
6
X15
6
7
Signal output
(Comp. ON)
8
TBO.4
1
X13
1
CNIH
M
3
(OG)
2
2WV2a
X9
1
3
1
3
4
X8
5
Signal output
(Cooling)
6
7
1
3
CNBHT
(BK)
CNBC
(GY)
1
1
3
X6
1
3
X7
5
7
CNBH
(WH)
1
t
OFF (Open)
ON (Short)
Refer to SW2-1 in
<6-19. DIP switch functions>.
Refer to SW2-2 in
<6-19. DIP switch functions>.
Refer to SW3-2 in
<6-19. DIP switch functions>.
Heat source OFF/
Normal
Boiler operation *2
Standard opera-
Heater operation/
tion
Boiler operation *2
Refer to SW3-1 in
<6-19. DIP switch functions>.
Refer to SW3-3 in
<6-19. DIP switch functions>.
Refer to installation manual.
Symbol
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
THW8
Thermistor (Zone2 flow temp.)(Option)
THW9
Thermistor (Zone2 return temp.)(Option)
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
IN3
Flow switch 2 (Local supply)
IN4
Demand control (Local supply)
IN5
Outdoor thermostat (Local supply)
IN6
Room thermostat 2 (Local supply)
IN7
Flow switch 3 (Local supply)
IN8
Electric energy meter 1 (Local supply)
1
<How to use TBO.1 to 4>
2
Connect them using either way as shown below.
4
6
Tool
Tool
CN01
(WH)
Conductor
Conductor
Outline view
Top view
1
CN01
2
TBO.1
(WH)
4
6
1
CNP1
(WH)
3
F2
F1
IEC T6.3AL250V
IEC T10AL250V
1
1
TBO.2
CNP4
3
(RD)
SW5
1
CN3C
(BU)
3
8
LED1
1
1
1
CNPWM
CNV1
TBO.3
3
SW4
(WH)
(WH)
3
5
6
1
CNRF
(WHT)
SW3
LED2
8
1
CN105
TBO.4
(RD)
LED3
SW2
CNIT
8
(BU)
1
1
CNIH
(OG)
3
SW1
CN22
1
(BU)
1
2
CNBHT
CNBC
8
(GY)
(BK)
CN108
3
LED4
CNBH
(WH)
CN1A
CNW5
CNW12
CN21
CN20
(WH)
(WH)
(RD)
(YE)
(RD)
1
1
1
1
1
2
2
3
4
4
2
4
6
8
10
12 14
2
4
6
8
10
12 14
2
4
6
8
10
12 14
3
5
7
9
11
13
1
3
5
7
9
11
13
1
3
5
7
9
11
13
TBI.1
TBI.3
TBI.2
TBI.1
1
2
3
4
5
6
7
8
9
10
11
12
13
2
1
4
1
3
1
2
t
t
t
t
°
°
°
°
°
Table 2 Outputs
Name Terminal block Connector
Water circulation pump 1 output (Space heating/cool-
OUT1
TBO.1 1-2 CNP1
ing & DHW)
Water circulation pump 2 output (Space heating/cool-
OUT2
TBO.1 3-4
ing for Zone1)
Water circulation pump 3 output (Space heating/cool-
ing for Zone2) *1
OUT3
TBO.1 5-6
2-way valve 2b output *2
OUT4
TBO.2 4-6 CNV1 3-way valve output
TBO.2 1-2
OUT5
Mixing valve output *1
TBO.2 2-3
OUT6
CNBH 1-3 Booster heater 1 output
OUT7
CNBH 5-7 Booster heater 2 output
OUT8
TBO.4 5-6
Cooling signal output
OUT9
TBO.4 3-4 CNIH Immersion heater output
OUT10 TBO.3 1-2
Boiler output
OUT11 TBO.3 3-4
Error output
OUT12 TBO.3 5-6
Defrost output
OUT13 TBO.4 1-2
2-way valve 2a output *2
OUT14
CNP4 Water circulation pump 4 output (DHW)
OUT15 TBO.3 7-8
Comp. ON signal
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
Name
28
Indoor unit powered
Indoor unit powered
via outdoor unit
by independent source
To outdoor
To outdoor
Power supply
unit
unit
~/N 230V 50Hz
L
N
S1
S2
S3
TB1
L
N
S1
S2
S3
TB1
BK
BK
BK
BK
1
1
2
CN01
CN01
2
(WH)
4
(WH)
4
6
6
BN
BN
1
1
CN3C
CN3C
OG
OG
(BU)
(BU)
3
3
Wireless receiver
(Option)
WiFi adapter
(Option)
TBI.3
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
+ - + - + -
CN22
CN1A
(BU)
(WH)
1
4
1
2
t
t
t
°
°
°
Item
Symbol
Name
IN9
Electric energy meter 2 (Local supply)
IN10
Heat meter (Local supply)
IN1A
Flow sensor
FLOW TEMP. CONTROLLER (FTC5)
TBO.1-4 Terminal block <Outputs>
TBI.1-3 Terminal block <Signal Inputs, Thermistor>
F1
Fuse (IEC T10AL250V)
F2
Fuse (IEC T6.3AL250V)
SW1-5
DIP switch *See <6-19. DIP switch functions>.
X1-15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main remote controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
9
10
11
12
13
14
t
t
t
°
°
°
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Heating
DHW
Close
Stop
Open
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Normal
Error
Normal Defrost
OFF
ON
OFF
ON
OFF
ON