6-13. EHST20C-MEC.UK, EHST20D-MEC.UK, ERST20C-MEC.UK, ERST20D-MEC.UK, EHST20D-MHC.UK
Immersion heater (1Ph3kW)(Option)
Power supply
to Immersion heater
~/N 230V 50Hz
L
N
(1)
(3)
ECB2
2 4
IHC
1
3
5
A1
A2
2
4
6
A B
IHT
IH
2
1
CNIH
3
(ORN)
1. S ymbols used in wiring diagram are,
: terminal block.
2. I ndoor unit and outdoor unit connecting wires have polarities, make
sure to match terminal numbers (S1, S2, S3) for correct wirings,
3. S ince the outdoor unit side electric wiring may change, be sure to
check the outdoor unit electric wiring diagram for service.
Symbol
Name
TB1
Terminal block <Power supply, Outdoor unit>
ECB2
Earth leakage circuit breaker for immersion heater
MP1
Water circulation pump 1 (Space heating/cooling & DHW)
MP2
Water circulation pump 2 (Space heating/cooling for Zone1)(Local supply)
MP3
Water circulation pump 3 (Space heating/cooling for Zone2)(Local supply)
MP4
Water circulation pump 4 (DHW)
3WV
3-way valve
2WV2a
2-way valve (For Zone1)(Local supply)
2WV2b
2-way valve (For Zone2)(Local supply)
MXV
Mixing valve (Local supply)
IHT
Thermostat (fixed temp.) for immersion heater
IH
Immersion heater
IHC
Contactor for immersion heater
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
THW8
Thermistor (Zone2 flow temp.)(Option)
THW9
Thermistor (Zone2 return temp.)(Option)
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
IN3
Flow switch 2 (Local supply)
IN4
Demand control (Local supply)
IN5
Outdoor thermostat (Local supply)
IN6
Room thermostat 2 (Local supply)
IN7
Flow switch 3 (Local supply)
IN8
Electric energy meter 1 (Local supply)
IN9
Electric energy meter 2 (Local supply)
IN10
Heat meter (Local supply)
FLOW TEMP. CONTROLLER (FTC5)
TBO.1-4 Terminal block <Outputs>
TBI.1-3 Terminal block <Signal Inputs, Thermistor>
F1
Fuse (T10AL250V)
F2
Fuse (T6.3AL250V)
SW1-5
DIP switch *See 6-19. DIP switch functions.
X1-15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
OCH570C
F1
CNPWM
(WHT)
1
F2
3
3
CNP1
TBO.1
(WHT)
X1
1
1
M
1~
2
3
M
MP1
X2
3
1~
M
2WV2b
1~
4
MP2
X3
5
TBO.1
M
1
6
1~
2
MP3
3
X14
1
4
M
1~
5
3
MP4
6
CNP4
(RED)
TBO.2
1
2
TBO.2
X5A
3
Close
1
4
M
N
1~
Open
2
5
X5B
MXV
6
3
X4
1
4
1
TBO.3
M
2
1~
5
5
3
3WV
6
CNV1
4
(WHT)
5
6
TBO.3
7
X10
1
Signal output
8
(Boiler)
2
TBO.4
X11
1
3
Signal output
2
(Error)
4
3
X12
5
4
Signal output
(Defrost)
5
6
X15
6
7
Signal output
(Comp ON)
8
TBO.4
1
CNBC
X13
1
CNIH
(GRY)
3
M
(ORN)
2
2WV2a
X9
1
3
1
4
3
CNBH
X8
5
(WHT)
Signal output
(Cooling)
6
7
1
3
CNBHT
(BLK)
CNBC
(GRY)
2
4
1
1
3
3
X6
1
3
X7
5
7
CNBH
(WHT)
: connector,
1
2
t
°
Table 1 Signal Inputs
Name Terminal block Connector
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts
may be reduced.
*2. To turn on the boiler operation, use the main controller to select "Boiler" in "External input setting" screen in
the service menu.
Table 2 Outputs
Name Terminal block Connector
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
OUT9
OUT10 TBO.3 1-2
OUT11 TBO.3 3-4
OUT12 TBO.3 5-6
OUT13 TBO.4 1-2
OUT14
OUT15 TBO.3 7-8
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
1
<How to use TBO.1 to 4>
2
Connect them using either way as shown below.
4
6
Tool
CN01
(WHT)
Conductor
Conductor
Outline view
Top view
CN01
(WHT)
1
CNP1
(WHT)
3
F2
6.3A 250V
10A 250V
1
CNP4
1
(RED)
3
SW5
CN3C
(BLU)
8
LED1
1
1
CNPWM
CNV1
SW4
(WHT)
(WHT)
5
6
1
CNRF
(WHT)
SW3
LED2
8
1
CN105
(RED)
LED3
SW2
CNIT
8
(BLU)
1
1
CNIH
(ORN)
3
SW1
CN22
(BLU)
1
CNBHT
8
(BLK)
CN108
3
LED4
CN1A
CNW5
CNW12
CN21
(WHT)
(WHT)
(RED)
(YLW)
1
1
1
1
2
3
4
4
6
8
10
12 14
2
4
6
8
10
12 14
2
4
6
8
10
12 14
5
7
9
11
13
1
3
5
7
9
11
13
1
3
5
7
9
11
TBI.1
TBI.3
TBI.2
TBI.1
1
2
3
4
5
6
7
8
9
10
11
12
1
4
1
3
1
2
t
t
t
t
°
°
°
°
Item
TBI.1 13-14
Room thermostat 1 input
TBI.1 11-12
Flow switch 1 input
TBI.1 9-10
Flow switch 2 input (Zone1) Refer to SW3-2 in <6-19. DIP switch functions>.
TBI.1 7-8
Demand control input
TBI.1 5-6
Outdoor thermostat input *1 Standard operation Heater operation/ Boiler operation *2
TBI.1 3-4
Room thermostat 2 input
TBI.1 1-2
Flow switch 3 input (Zone2) Refer to SW3-3 in <6-19. DIP switch functions>.
TBI.3 1-2
Electric energy meter 1
TBI.3 3-4
Electric energy meter 2
TBI.3 5-6
Heat meter
TBO.1 1-2 CNP1 Water circulation pump 1 output (Space heating/cooling & DHW)
TBO.1 3-4
Water circulation pump 2 output (Space heating/cooling for Zone1)
Water circulation pump 3 output (Space heating/cooling for Zone2) *1
TBO.1 5-6
2-way valve 2b output *2
TBO.2 4-6 CNV1 3-way valve output
TBO.2 1-2
Mixing valve output *1
TBO.2 2-3
CNBH 1-3 Booster heater 1 output
CNBH 5-7 Booster heater 2 output
TBO.4 5-6
Cooling signal output
TBO.4 3-4 CNIH Immersion heater output
Boiler output
Error output
Defrost output
2-way valve 2a output *2
CNP4 Water circulation pump 4 output (DHW)
Comp ON signal
27
Indoor unit powered
Indoor unit powered
by independent source
via outdoor unit
To outdoor
Power supply
unit
~/N 230V 50Hz
Tool
L
N
S1
S2
S3
TB1
L
N
BLK
1
BLK
BLK
2
BLK
4
1
6
1
2
CN01
CN01
2
(WHT)
4
(WHT)
4
F1
6
6
1
BRN
1
1
3
CN3C
CN3C
(BLU)
ORN
(BLU)
3
3
1
3
Wireless receiver
(Option)
WiFi adapter
(Option)
1
2
CN20
(RED)
1
2
13
TBI.3
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
+ - + - + -
CN22
(BLU)
1
2
t
°
OFF (Open)
Refer to SW2-1 in <6-19. DIP switch functions>.
Refer to SW2-2 in <6-19. DIP switch functions>.
Normal
Heat source OFF/ Boiler operation *2
Refer to SW3-1 in <6-19. DIP switch functions>.
Refer to installation manual.
Item
To outdoor
unit
S1
S2
S3
TB1
BRN
ORN
4
5
6
7
8
9
10
11
12
13
14
t
t
t
t
t
°
°
°
°
°
ON (Short)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Heating
DHW
Close
Stop
Open
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Normal
Error
Normal Defrost
OFF
ON
OFF
ON
OFF
ON