LCN 9700 Series Installation Instructions Manual page 6

Middle swing control box. senior swing control box
Table of Contents

Advertisement

Bodyguard (master; safety side): Prevents
door from opening; holds open door in open
position (uses door state data from control box
to ignore door movement while opening/closing)
DMSS (master; safety side): Prevents door from
opening, and slows an opening door
DMSS (master; approach side): Initiates a door
opening cycle if activated while door is closing
DMSS (companion; safety side): Prevents door
from opening, and slows an opening door
DMSS (companion; approach side): Initiates a
door opening cycle if activated while door is closing
Activate: Initiates a door opening cycle
Activate: Initiates a door opening cycle
(operates identically to P6 and is provided as
a convenience if 2 activations are used)
Retrofit Accessories: Accesses older model
Activate, Slow/Stop, and Carpet Safety inputs
Breakaway: Disables operator inputs when
Breakaway switch is active
3-Position Switch: OFF, AUTO, HOLD
Locking Interface: Power output and relay
contacts for locking devices; Power Boost
disable input
Companion Motor Power: Companion motor
power (use only for second door of simultaneous
pair or independent pair of doors)
Master Motor Power: Master motor
power (use for single door)
AC Input: 120 VAC
Page 6 of 14
3. WIRING (continued)
If used
P1
on-board
connector
P2
If used
on-board
connector
P3
If used
on-board
connector
P4
If used
on-board
connector
P5
If used
on-board
connector
P6
If used
on-board
connector
P7
If used
on-board
connector
Retrofit
P8
only
on-board
connector
If used
P10
on-board
connector
If used
P5
on-board
connector
Figure 3-5
Cable
761468
Black, 24 VAC
Red, 24 VAC
Safety
White, Slowdown
Green, Ground
DMSS
harness
Black, 24 VAC
761467
Red, 24 VAC
Approach
White, Activate
Green, Ground
Black, 24 VAC
Red, 24 VAC
Safety
White, Slowdown
Green, Ground
DMSS
harness
Black, 24 VAC
761467
Red, 24 VAC
Approach
White, Activate
Green, Ground
Black, 24 VAC
White, 24 VAC
Cable
Yellow, Activate
761464
Gray, Ground
Black, 24 VAC
White, 24 VAC
Cable
Yellow, Activate
761464
Gray, Ground
Blue, Carpet Safety
Gray, Ground
Cable
Yellow, Activate
761469
Violet, Slowdown
Orange
Black
Red
Green
Black
Blue, Power Boost disable
Black, Ground
Violet, Relay NO
Cable
Gray, Relay COM
Brown, Relay NC
761465
Green, 5 V
White, 24 VAC
White, 24 VAC
Cable
761466
Black, Hot AC
Cable
White, Neutral AC
761463
Green, Earth Ground
Bodyguard cable
to Bodyguard
sensor
Bodyguard
JST-type
connector
To DMSS
(master;
safety side)
To DMSS
(master;
approach side)
To DMSS
(companion;
safety side)
To DMSS
(companion;
approach side)
Used only for powered activation device
Activate cable
To normally open Activate contacts
Used only for powered activation device
Activate cable
To normally open Activate contacts
To existing cable
710057 (old part
No. 81276)
To normally closed
Breakaway switch
or jumper 81269
To 3-position
switch (if used)
To normally open
Ground
Power Boost
disable contacts
To locking device
(see page 7 for
sample wiring)
To motor cable of
companion operator
(use only for second
door of simultaneous
pair of doors)
To motor cable of
master operator
(always use for
single door)
To 120 VAC
740100-00(5)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9500 series2900 series2800 series

Table of Contents