LCN 9700 Series Installation Instructions Manual page 11

Middle swing control box. senior swing control box
Table of Contents

Advertisement

Setting
Opening Speed
back check Speed
back check Position
hold open delay
Latch Position
Auto reverse Closing
Electric Lock
Power boost
Not functional on
Middle Swing
control box
Push 'N' Go
Alternate Activate
Safety Slow/Stop
Slowdown disable
740100-00(5)
4. KEYPAD SETTINGS (continued)
Table 4-1. Control Box Settings and Selectable Values
Setting
Selectable
Display
Values
01 = slow
02 = medium
03 = fast
(default = 01)
01 = 1 door
02 = 2 doors
(default = 01)
45-80 degrees
(default = 70)
01-32 seconds
(default = 05)
00-23 degrees
(default = 13)
off, on
(default = off)
off
SA = fail safe
SE = fail secure
(default = off)
off
5 seconds
continuous
(default = off)
off, on, fd
(default = off)
off, on
(default = off)
slow, stop
(default = slow)
off , 30-85
(increments of 5)
Reserved
Values as
Displayed
Controls opening speed of any normal
weight and size door
Controls speed of door near full open
position to prevent door slamming open
Approximate angle at which door begins
to decelerate near the full open position
Amount of time (in seconds) door remains
fully open following an activate signal
Approximate angle at which door begins
to decelerate near the full closed position
When on, door will re-open upon hitting
an obstruction
To turn on, set to SA (fail safe) or SE (fail
secure) to match locking device connected
to control box locking interface receptacle
(P10); when on, causes a 1 second delay
between activate signal and door opening
to allow time for most electric locks to
disengage before operator opens door
When on, increases closing force of door
from 9 lbs to 18 lbs to close door against
high winds or stack pressure; turns on
for 5 seconds or continuously after door
reaches latch position during closing cycle;
disabled by Power Boost disable input
When set to On or Fd, pushing door
open 5 degrees causes operator to open
door remainder of way and hold open.
Hold open time is same as hd setting
when set to On. Hold open time is 1
second when set to Fd.
When on, door stays open until a
second activate signal is received
Determines response to a DMSS on the
safety side of the door; if SL (slow),
door goes to back check speed; if SP
(stop), door stops for 5 seconds, then
continues opening at back check speed
Used when DMSS detects nearby wall or
guard rail while opening. Set to highest
approximate angle that normal door
operation will allow. When enabled,
slowdown ignored at all angles greater
than value displayed.
Reserved
Reserved
Description
Page 11 of 14