Low pulsating electromagnetic fields (LPEMF) do not create electrosmog!
Even at the highest intensity settings, the average peak field strength of the Magnetic-Reso-
nance-Stimulation System is less than or equal to 300 µT (microTesla). This is less than the field
strengths produced by common domestic appliances and well below the recommended limit of
400 µT (microTesla) for compliance with DIN 0848.
Safety is ensured by the fact that the frequencies and field strengths employed are on the same
magnitude as naturally-occurring electromagnetic fields within the Earth's ionosphere.
Instructions on electromagnetic compatibility (EMC)
Medical, electric devices are subject to special precautions in terms of EMC and must be ins-
talled and brought into operation in accordance with the EMC instructions in the accompanying
documents. Electromedical devices can be particularly affected by portable and mobile RF com-
munications equipment, e.g. mobile phones or walkie-talkies.
The manufacturer only guarantees the compliance of the device with the EMC requirement
when used with the accessories listed in 16.2. The use of other accessories can lead to an incre-
ased emission of electromagnetic interference or to a reduced resistance against such interfe-
rence. The accessories listed may only be used together with an iMRS system from Swiss Bionic
Solutions Schweiz GmbH.
The device may not be operated in combination with other devices, nor be stacked with or loca-
ted in the proximity of these. Should such an arrangement, however, be necessary, the device
must be kept under observation to check its operation for the use intended when in such an
arrangement.
The propagation of the magnetic field from the whole-body / pad applicators has largely abated
at a distance of about 1.5 metres. Persons not receiving treatment should remain outside such a
range during the course of an application.
We are legally obliged, in accordance with the EMC regulations for medical products, to
provide you with the following information:
Guidelines and manufacturer's declaration - electromagnetic interference emissions
The iMRS is intended for operation in an ELECTROMAGNETIC ENVIRONMENT as given below.
The customer or user of the iMRS should ensure that it is operated in such an environment.
© Swiss Bionic Solutions Schweiz GmbH / 8834 Schindellegi / 2016