ZONGSHEN ZS250GY-3 Service Manual page 56

Efi
Table of Contents

Advertisement

[2]Remove the flasher socket of signal system and
measure the flasher with multimeter.Check whether
it has short circuit.Replace it if short circuit.
[3]Check whether starting relay is in good working
condition.Replace it with the same type if it is not
in good working condition.
[4]Dismantle the switches of left and right controls.
Check whether they are damaged or have short
circuit.Repair or replace them if have problems.
CAUTION
Check whether front/rear brake switches are in
good working condition.Readjust or replace them
if they are not in good working condition.
If front/rear brake light do not shine when
braking,then there is no electric power to start.
[5]Remove fuse tube and check whether it melts.
Replace it with the same type.
Fuse tube type:12V/20A
CAUTION
Replace fuse tube with the same type when it
52
is damaged.
Flasher
Starting
relay
Control
switch
Check fuse
tube.

Advertisement