Advertisement

Quick Links

Surveyor 4B
User Manual
Référence : NPS4BGB
Révision : E.0
The Fixed Gas Detection Experts

Advertisement

Table of Contents
loading

Summary of Contents for Oldham Surveyor 4B

  • Page 1 Surveyor 4B User Manual Référence : NPS4BGB Révision : E.0 The Fixed Gas Detection Experts...
  • Page 2 Copyright  November 2018 by Oldham S.A.S. All rights reserved. The reproduction of all or any section of this document in any form whatsoever without the written permission of Oldham S.A.S. is forbidden. The information contained in this manual is accurate to our knowledge.
  • Page 3: Table Of Contents

    Important Information .................. 2 Liability Limits ....................2 Warranty ...................... 2 Chapter 2│ Description ..............3 Chapter 3│ Mounting of the SURVEYOR 4B ........5 Chapter 4│ Connections ..............7 Alternative power supply................7 DC power supply ..................8 Explosimetric detectors ................8 External components ...................
  • Page 4 Surveyor 4B User Manual...
  • Page 5: Chapter 1│ General Information

    The aim of this manual is to supply simple and accurate information to the user. Oldham cannot be held liable for any misinterpretations in the reading of this manual. In spite of our efforts to produce an error-free manual, it may nonetheless contain some unintentional technical inaccuracies.
  • Page 6: Safety Instructions

    4B controller, injuries, loss of time, financial or material loss, or any direct or indirect consequence of loss occurring in the context of the use or impossibility of use of the product, even in the event that Oldham has been informed of such damage.
  • Page 7: Chapter 2│ Description

    2. Surveyor 4B is Class II equipment. Surveyor 4B is equipped with a small "NORMAL" box (58 x 105 x 90 mm). It can be snap-fastened onto a standard symmetrical DIN rail and should imperatively be integrated in a closed electrical equipment cabinet.
  • Page 8 The components used in operation are located on the front of the appliance: adjustments and tests on the top (Item 1, Figure 1), indicator lights on the FRONT face (Item 2,Figure 1), connections at the bottom (Item 3, Figure 1). Item 1 Item 2 Item 3 Figure 1 Surveyor 4B User Manual...
  • Page 9: Chapter 3│ Mounting Of The Surveyor 4B

    Chapter 3│ Mounting of the SURVEYOR 4B The surveyor 4B appliance fitted on its symmetrical DIN rail must be installed in a closed electrical equipment cabinet. A space of 100 mm is necessary around of the Surveyor 4B. The Surveyor 4B should preferably be located in a monitored location (such as a guardhouse, control room or instrumentation room).
  • Page 10 Surveyor 4B User Manual...
  • Page 11: Chapter 4│ Connections

    . The nature of the current and line voltage must be checked. The line voltage must match the voltage specified on the plate fitted on the Surveyor 4B. The voltage is configured in the factory.
  • Page 12: Dc Power Supply

    The 12 volt power supply can be connected to the points marked 0 and 12 V on the Surveyor 4B terminal block (see Figure 2, Item2). The Surveyor 4B must be protected on the upstream side by a fuse (630mA) with time-delay.
  • Page 13: External Components

    Detector terminal • The maximum loop resistance is 1.4 ohms. For example: the maximum distance between Surveyor 4B and the detector will be 40 m with conductors with a cross section of 1.5 mm². External components Surveyor 4B is equipped with the following two relays: •...
  • Page 14 Caution: The high-power solenoid valves cannot be directly remote controlled . A power relay is required. The maximum current through the relay contacts will be 2 A and the maximum voltage will be 250 Vac ou 30 Vdc. Surveyor 4B User Manual...
  • Page 15: Examples Of Installation

    Examples of installation Example of installation set up of a SV 4B with TWO OLC 10 TWIN detectors Figure 5 Example of installation set up of a SV 4B with TWO OLC 10 TWIN detectors Breaking capacity of rating relays switch contact: 2A / 250Vca - 30Vdc Important : The relay's contacts are shown on the SV 4B label, unit switch off.
  • Page 16 Example of installation set up of a SV 4B with a single detector Figure 6: Exemple d'installation d'un Surveyor 4B avec un capteur Breaking capacity of rating relays switch contact : 2A / 250Vca – 30Vcc Important : The relay's contacts are shown on the SV 4B label, unit switch off.
  • Page 17: Chapter 5│ Operating Instructions

    Chapter 5│ Operating instructions Switching on It is assumed that all the necessary connections have been made and that the whole installation complies with the standards currently in force. As soon as the SV 4B is supplied with power, it is ready to use and the GREEN light-emitting diode lights up (rep 1, Figure 7).
  • Page 18 (humidity, temperature, dust, etc.); however, it must not exceed one year. The general manager should put safety procedures in place on-site. OLDHAM cannot be held responsible for their enforcement. Surveyor 4B...
  • Page 19 Adjusting the "gas alarm" thresholds Using a "reference gas kit" (gas cylinder + pressure regulator, etc.), inject the reference gas with a content level higher than the first threshold desired. (For example, threshold 1 will be 20% LEL, so a minimum of 25% LEL should be injected).
  • Page 20 (or to below the threshold). This is done by pressing the Ack. key (item 5, Figure 8). Automatic mode: When a gas alarm is triggered, it is cleared automatically as soon as the content level falls below the alarm threshold. Surveyor 4B User Manual...
  • Page 21 As long as there is a high enough concentration of gas to trigger an alarm, it is impossible to clear that alarm manually (with the Ack. button). 5 - Operating instructions...
  • Page 22 - Allow to stabilize for at least 10 seconds. - Check that the alarm or alarms are triggered (as applicable ) and carry out the following procedure. La valeur du gaz étalon sera supérieure au moins au premier seuil d'alarme. Surveyor 4B User Manual...
  • Page 23 5 - Operating instructions...
  • Page 24 The fuse (Figure 10, item 1) must be replaced by qualified personnel only. The fuse is, and must be, in compliance with CEI 127, with time-delay, low breaking capacity and a voltage of 250 V ~. - Fuse 5x20- T125 mA 250 V- OLDHAM reference = 6154701 item 1 Figure 10...
  • Page 25: Chapter 6│ Technical Specifications

    Chapter 6│ Technical specifications Manufacturer OLDHAM Type SURVEYOR 4 B Control station for explosive gas detectors Function 1 measurement chanel Capacity 1 detector type CEX 300 or OLC10/100 or 2 OLC 10Twin detectors Measurement Measurement Continious Display unit None Failure: yellow...
  • Page 26 Surveyor 4B User Manual...
  • Page 27: Chapter 7│ Disposal

    Chapter 7│ Disposal Concerning the conservation, of the protection and the improvement of the quality of the environment, as well as for the protection of the health of the persons and the careful and rational use of natural resources, SV 4B has to be the object of a selective collection for the electronic equipments and cannot be scrapped with the normal domestic waste.
  • Page 28 Surveyor 4B User Manual...
  • Page 29: Chapter 8│ Main Part Numbers

    Chapter 8│ Main Part Numbers Désignation Reference Surveyor 4B controller for 340mA wheatstone bridge 6 514 807 sensor Fuse 5x20 - T125 mA 250 V 6 154 701 8 – Main Part Numbers...
  • Page 30 Surveyor 4B User Manual...
  • Page 31: Chapter 9│ Maintenance

    Fuse replacement should only be performed by qualified personnel and power must be first switched off. Fuses shall comply with IEC 60127 standard (time-delay fuse, low breaking capacity, 250Vac). Please see Chapter 8│. Oldham does not allow any other repairs than those listed here above. 9 – Maintenance...
  • Page 32 Surveyor 4B Manuel utilisateur...
  • Page 33: Chapter 10│ Certificate Of Compliance

    Chapter 10│ Certificate of Compliance The document hereafter (1 page) reproduces the EU declaration of conformity. 10 – Certificate of Compliance...
  • Page 34 Surveyor 4B Manuel utilisateur...
  • Page 36 The Fixed Gas Detection Experts EUROPEAN PLANT AND OFFICES Z.I. Est – rue Orfila CS 20417 – 62027 ARRAS Cedex FRANCE Tél.: +33 (0)3 21 60 80 80 – Fax: +33 (0)3 21 60 80 00 Web site: https://gasdetection.3M.com AMERICAS ASIA PACIFIC EUROPE Tel : +1-713-559-9280...

Table of Contents