12 - 24 V
DC
Power
+
Door Contact
MODE 1&2 WIRING DIAGRAM
-
12 - 24 V
DC
Power
+
Door Contact
MODE 4 WIRING DIAGRAM

5. SPECIFICATIONS

Voltage:
12 /24V DC operation
Current Draw:
50mA (max)
Relays:
(2) Form 'C' (DPDT)
Contact Rating:
3A @ 30VDC
Programming:
On-board push buttons
and status LED
Modes:
- (4) Factory Default
- (1) Fully Custom
- Selectable Fail Safe/
Fail Secure
Coverage:
- Max. 10' W x 10' H
- Horizontal & vertical
adjustment (mechanical)
- Sensor sensitivity/range
(electronic)
Time Delay:
Adjustable, 0.5, 1, 2.5,
5, 15, 30, 45 & 60
second
Sounder:
On/Off, with adjustable
volume
Piezo Buzzer:
92db.@ 10cm.
Maglock
MOV
Notes:
1. Relay is set to Safe Mode in
this application
J2
2. Relay O/P2 is EMF protected.
If using O/P1a diode should be
place across the maglock
J4
power connections.
Sounder
Request to Exit
Control
Push Button
Maglock
MOV
Notes:
1. Relay is set to Safe Mode in
this application
J2
2. Relay O/P2 is EMF protected.
If using O/P1a diode should be
place across the maglock
J4
power connections.
Request to Exit
REX Sensor
Push Button
Keypad
Eye Beams
Indicator:
Card or
Keypad Input:
Door Position
Switch Input:
Request to
Exit Input:
Tamper Switch
Contact Rating:
Temp Operating
Range:
Humidity Range: 0 - 93% non-condensing
Dimensions:
Weight:
Colors:
CM-RQE70A PIR 'REQUEST TO EXIT' DETECTOR
-
12 - 24 V
DC
Power
+
Door Contact
MODE 3 WIRING DIAGRAM
J2
Description
1
Power +
2
Input 1
3
Input 2
4
Input 3
5
Ground
6
Tamper Switch 1
7
Tamper Switch 2
J4
Description
1
Relay 1b - Normally Closed (NC2)
2
Relay 1b - Normally Open (NO2)
3
Relay 1b - Common (C2)
4
Relay 1a - Normally Closed (NC1)
5
Relay 1a - Normally Open (NO1)
6
Relay 1a - Common (C1)
7
Power -
Activation LED
(1) N/O
(1) N/O
(1) N/O
50mA @ 12VDC
32°F - 120°F (0 - 50°C)
1 3/4"H x 7" W x 1 3/4" D
(43mm x 176mm x 43mm)
0.25 lbs. (0.12kg.)
White and black models
INSTAL LATION INS T RUCT IONS
Maglock
MOV
Notes:
1. Relay is set to Safe Mode in
this application
J2
2. Relay O/P2 is EMF protected.
If using O/P1a diode should be
place across the maglock
J4
power connections.
Access
1 2 3
Request to Exit
Control
4 5 6
Push Button
Keypad/
7 8 9
Reader
EMF Spike
protected relay
UL 294 Access Control Performance
Levels
1) Access Controls, Destructive Attack
Level I (No Attack)
2) Line Security - Level I (No Line
Security)
3) Endurance - Level IV (100,000 cycles)
4) Standby Power - Level I (No Stand by
Power)
Power is to be supplied by a compatible
UL294 Listed control unit, or by a UL294
Listed or UL603 Listed Class 2 low-voltage
power limited power supply that is capable of
4 hours of standby power, as described in the
installation guide.
The products shall not be installed in the
fail-secure mode unless permitted by the
local authority having jurisdiction and shall
not interfere with the operation of Listed
panic hardware.