CM-RQE70A PIR 'REQUEST TO EXIT' DETECTOR
INSTA L L AT I O N I NST RU CTI ONS

Programming Buttons

There are no DIP switches to set on this Rex Sensor. 3 buttons are used
for all setup and programming.
J4
SOUNDER
MODE
PARAMETER
J2
ADJUST
The MODE Button (top):
The MODE button is used to select 1 of 4 pre-set modes or a fully
configurable custom Mode. Pressing the MODE button for the first time
will indicate which Mode the REX sensor is currently in. The REX sensor
will BEEP and the LED will flash red the number of times equal to the
MODE number. I.E. 1 Beep/Flash = Mode 1.
The Parameters Button (Middle)
This button selects the available parameters in each mode that can be
customized. From within any Mode, press this button to cycle through
the parameters.
Parameter
1 beep
Relay On
0.5
Time
Fail Mode
Safe
Operation
Latched
Mode
PIR
1
Sensitivity
Sound
0
Volume
Input #1
Unused
Input #2
Unused
Input #3
Unused
Factory Reset
The Camden CM-RQE70A Request to Exit sensor can be reset to factory
defaults by pressing and holding the MODE and Adjust buttons. The
Sensor will start to beep. Continue holding the MODE and ADJUST
buttons while the beeping gets progressively faster until it reaches a
steady tone. When the tone stops, the REX sensor has been reset to
factory defaults and the MODE and ADJUST buttons may be released.
Page 4 of 6
TAMPER
LED
LENS
SWITCH
2 beeps
3 beeps
4 beeps
1
2.5
5
Secure
Door Prop
Unauthor-
Timed
Open Alarm
ized Access
2
3
4
1
3
3
Card/
Door
Press to Exit
Keypad
Contact
Card/
Door
Press to Exit
Keypad
Contact
Card/
Door
Press to Exit
Keypad
Contact
Mode
Beeps
1
1
LOCK
2
2
DOWN
SCREW
3
3
4
4
5
5
The Adjust Button (Bottom)
The adjust button is used to change the value of the Parameter.
Once a Parameter is selected, use the Adjust button to cycle through
the available options for each parameter as described in the below
table.
5 beeps
6 beeps
15
30
5
4
Sounder
Sequential
Input
Input
Sounder
Sequential
Input
Input
Sounder
Sequential
Input
Input
Regulatory Information
The unit shall be installed in accordance with National Electrical Code
ANSI/NFPA 70 and part 1 of the Canadian Electrical Code CSA C22.1,
Safety Standard for Electrical Installations and authorities having
jurisdiction (AHJ's).
Red
LED
Description
Flashes
1
Latched Mode
2
Door Prop Alarm Mode
3
Access Control Mode
4
Secondary Activation Mode
5
Custom Settings Mode
7 beeps
8 beeps
45
60
External
External
Disable
Disable
External
External
Disable
Disable
External
External
Disable
Disable
LED
Yellow Solid
Red/Yellow
Flashing
Green/Yel-
low Flashing
Red/Green
Flashing
Red/Green/
Yellow
Flashing
Red
Flashing
Green
Flashing
Yellow
Flashing

Advertisement