each of the all-thread rods. Last, put a 5/16" nut on
each rod and hand tighten without letting the rod
rotate. (See Figure 5.)
7. With one hand, grip the end of the all-thread rod with
either a plier, or vice grip. Then, with the other hand,
tighten the nut with a 1/2" wrench while making sure
the Vault stays level. Repeat this procedure for all
four rods, and tighten to approximately 50-75in-lb
or until firmly snug. Cut off the excess all-thread rod
using an appropriate tool.
Tamper Switch (Optional)
If you are using the optional tamper switch, attach the
tamper switch to the wiring in the wall (see Figure 3).
Note: Tamper switch wiring must conform to NEC class 2
or 3; or UL class 634 standards. Electrical range should
be 30 VDC at 50 MA. Use AMP FDVH 187C (14/16
AWG) crimp connectors, or equivalent.
TRAC-Lid BT installation
To install the TRAC-Lid BT in the TRAC-Vault BT, attach
the provided chain to the TRAC-Lid BT. Insert the loose
end of the chain through the eyehole on the back of the
TRAC-Lid BT, then crimp the end of the chain to the
bracket inside the TRAC-Vault BT.
To place the TRAC-Lid BT in the TRAC-Vault BT, the
lock blades on the side of the TRAC-Lid BT must be
retracted.
To retract the blades on the TRAC-Lid BT, do
the following:
1. Use a DisplayKEY or eKEY to perform the open
device function. Refer to the user instructions
provided with your key for step by step operation.
2. When the indicator light on the TRAC-Lid BT flashes
green, rotate the thumb lever 90° down until it stops.
Important: When installing a TRAC-Lid BT you MUST
record the serial number of the TRAC-Lid BT installed at
each location. This important information is necessary
for the integrity of the TRACcess database.
Regulatory Compliance
United States (FCC)
This device complies with part 15 of the FCC rules. Operation
is subject to the following conditions:
1.
This device may not cause harmful interference.
2.
This device must accept any interference received,
including interference that may cause undesired operation
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
Canada (IC)
This Class B digital apparatus complies with Canadian ICES-
003. Cet appareil numérique de la classe B est conforme à la
norme NMB-003 du Canada.
Cet appareil se conforme à l'Industrie la norme (s) RSS
exempte du permis du Canada. L'opération est soumise
aux deux conditions suivantes : (1) cet appareil peut ne pas
provoquer l'interférence et (2) cet appareil doit accepter toute
interférence, en incluant l'interférence qui peut provoquer
l'opération indésirable de l'appareil.
European Union (CE)
This Class B digital apparatus conforms to the requirements of
the following EU directives:
1.
R&TTTE Directive (1999/5/EC)
2.
WEEE Directive (2002/96/EC)
Warranty
UTC Fire & Security (UTCFS) warrants that this product will
be free of defects in material and workmanship for one year
from the date of purchase. This warranty is limited to repair
or replacement at the option of UTCFS. Damages caused
by modification, abuse or misuse, wear and tear, improper
installation, application, storage, or fault or negligence of
a party other than UTCFS are not covered. UTCFS will be
responsible for labor costs of removal or reinstallation of
products. The repaired or replaced product is then warranted
under the terms of this limited warranty for the balance of
the term of the warranty or for 90 days, whichever is longer.
UTCFS MAKES NO OTHER WARRANTY, EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. IN NO EVENT SHALL UTCFS
BE LIABLE FOR LOSS OF USE; LOST PROFITS; THEFT;
PROPERTY DAMAGE; OR SPECIAL, INCIDENTAL,
OR CONSEQUENTIAL DAMAGES. To obtain repair or
replacement information under the terms of this warranty,
please contact your local supplier.
3

Advertisement

loading